Honeywell s HercuLine 2000 User Manual
Page 6

62-86-25-14
Quick Start Guide for Herculine 2000 Series Actuators
February 2007
Page 6 of 10
6. Enter, verify and adjust set up parameters for proper operation. (2001/2002 with optional display)
Pressing the SET UP key on the keypad provides access to the various set up groups and allows you to set up
operating parameters, (such as input types and alarms), set communications, and check actuator status. The Table
below lists the set up groups that are available by using the SET UP and FUNCTION keys on the keypad.
TEMP
TEMPHI
TEMPLO
ACSTAL
STARTS
RL1CNT
RL2CNT
RL3CNT
RL4CNT
REGN0
REGN9
TOTDEG
DATSAV
PASSWD
MANRST
LD CAL
LD CFG
RESTRT
…
VERSON
SPEED
POWER
ROTATE
TAG
MFGDAT
LREP
LCAL
REPTYP
CUROUT
COMM
ADDRES
BAUD
XmtDLY
DBLBYT
DIGINP
EndPos
DECMAL
EUNITS
UNITS
LOCKID
LOCK
MAENAB
FAILSF
RAMTST
SEETST
CFGTST
CALTST
RTYPny
Rny VAL
Rny E*
Rny HL
RTYPny
Rny VAL
Rny E*
Rny HL
RLYnHY
n = 1,2,3 or 4 y = 1 or 2
RELAYn
IN TYP
INP HI
INP LO
FILTYP
Direct
Dband
FSTYPH
CHAR
CUSTOM
X0 VAL
X20 VAL
Y0 VAL
…
Y20 VAL
…
FsVALH
FSTYPL
FsVALL
MAINT
DRVINF
STATUS
LOCK
DISPLA
DIGINP
COMM
INPUT
CUROUT
Setup Groups
Function Prompts
TEMP
TEMPHI
TEMPLO
ACSTAL
STARTS
RL1CNT
RL2CNT
RL3CNT
RL4CNT
REGN0
REGN9
TOTDEG
DATSAV
PASSWD
MANRST
LD CAL
LD CFG
RESTRT
…
TEMP
TEMPHI
TEMPLO
ACSTAL
STARTS
RL1CNT
RL2CNT
RL3CNT
RL4CNT
REGN0
REGN9
TOTDEG
DATSAV
PASSWD
MANRST
LD CAL
LD CFG
RESTRT
…
VERSON
SPEED
POWER
ROTATE
TAG
MFGDAT
LREP
LCAL
REPTYP
VERSON
SPEED
POWER
ROTATE
TAG
MFGDAT
LREP
LCAL
REPTYP
CUROUT
COMM
ADDRES
BAUD
XmtDLY
DBLBYT
DIGINP
EndPos
DECMAL
EUNITS
UNITS
LOCKID
LOCK
MAENAB
FAILSF
RAMTST
SEETST
CFGTST
CALTST
RTYPny
Rny VAL
Rny E*
Rny HL
RTYPny
Rny VAL
Rny E*
Rny HL
RLYnHY
n = 1,2,3 or 4 y = 1 or 2
RELAYn
IN TYP
INP HI
INP LO
FILTYP
Direct
Dband
FSTYPH
CHAR
CUSTOM
X0 VAL
X20 VAL
Y0 VAL
…
Y20 VAL
…
FsVALH
FSTYPL
FsVALL
MAINT
DRVINF
STATUS
LOCK
DISPLA
DIGINP
COMM
INPUT
CUROUT
Setup Groups
Function Prompts
You can use this procedure to access the set up groups and select all parameters.
Set Up Procedure Using Display and Keypad
Step
Operation
Press
Result
1
Enter Set Up
Mode
SET UP
Upper Display = SET UP-Lets you know you are in the set up mode and a set up group
title is being displayed in the lower display.
Lower Display = INPUT-This is the first set up group you see when you press SET UP.
2
Select any
Set Up
Group
SET UP
Successive presses of the SET UP key will display the other set up group titles. You can
also use the
or
keys to scroll through the set up groups in both directions. Stop
at the set up group title that describes the group of parameters you want to configure.
Then proceed to the next step.
3
Select a
Function
Parameter
FUNCTION
Upper Display - Shows the current value or selection for the function prompt in the
selected set up group.
Lower Display - Shows the first function prompt within the selected set up group.