beautypg.com

Save these instructions, Air compressor safety warnings, Safet y m aintenan c e parts list setup – Harbor Freight Tools 67697 User Manual

Page 4

background image

Page 4

For technical questions, please call 1-800-444-3353.

Item 67697

SAFET

y

M

AINTENAN

c

E

PARTS LIST

SETUP

Air compressor Safety Warnings

1.

Risk of fire or explosion - do not spray flammable

liquid in a confined area or towards a hot surface.

Spray area must be well-ventilated. Do not

smoke while spraying or spray where spark or

flame is present. Arcing parts - keep compressor

at least 20 feet away from explosive vapors,

such as when spraying with a spray gun.

2.

Risk of bursting - do not adjust regulator higher

than marked maximum pressure of attachment.

3.

Risk of injury - do not direct air

stream at people or animals.

4.

Do not use to supply breathing air.

5.

Do not leave compressor unattended

for an extended period while plugged in.

Unplug compressor after working.

6.

Keep compressor well-ventilated.

Do not cover compressor during use.

7. Drain tank daily and after use. Internal rust causes

tank failure and explosion.

8. Add correct amount of compressor oil before first

use and every use. Operating with low or no oil

causes permanent damage and voids warranty.

9. Do not remove the valve cover or

adjust internal components.

10. Compressor head gets hot during operation.

Do not touch it or allow children nearby during

or immediately following operation.

11. Do not use the air hose to move the compressor.

12. Release the pressure in the

storage tank before moving.

13. The use of accessories or attachments not

recommended by the manufacturer may

result in a risk of injury to persons.

14. All air line components, including hoses, pipe,

connectors, filters, etc., must be rated for a minimum

working pressure of 150 PSI, or 150% of the

maximum system pressure, whichever is greater.

15. USE OF AN EXTENSION CORD IS NOT

RECOMMENDED. If you choose to use an

extension cord, use the following guidelines:

TABLE A: REcOMMENDED MINIMUM WIRE

GAUGE FOR EXTENSION cORDS

(120 VOLT)

NAMEPLATE

AMPERES

(at full load)

EXTENSION cORD

LENGTH

25′

50′

100′

150′

0 – 6

18

16

16

14

6.1 – 10

18

16

Do not use.

10.1 – 12

16

16

Do not use.

12.1 – 16

14

12

Do not use.

a. Make sure your extension cord

is in good condition.

b. Be sure to use an extension cord which is heavy

enough to carry the current your product will draw.

An undersized cord will cause a drop in line

voltage resulting in loss of power and overheating.

Table A shows the correct size to use depending

on cord length and nameplate ampere rating.

If in doubt, use the next heavier gauge. The

smaller the gauge number, the heavier the cord.

16. Operate unit on level surface. Check oil level

daily and fill to marked level if needed.

17. People with pacemakers should consult their

physician(s) before use. Electromagnetic fields in

close proximity to heart pacemaker could cause

pacemaker interference or pacemaker failure.

SAVE THESE INSTRUcTIONS.