beautypg.com

Electrical supply, Fuses, Changing the plug – Hotpoint FZ92P User Manual

Page 3: Changing the mains lead

background image

WARNING: This appliance must be earthed.

Fuses

Your appliance comes fitted with a plug and a 13A fuse. If you need to replace the fuse, only

those rated at 13A and ASTA approved to BS1362 should be used. If you lose the fuse cover,

a replacement may be obtained from your local Electricity company.

Correct replacement is identified by colour coding or the marking on base of plug.

WARNING: Do not use plug unless fuse cover is fitted.

Changing the Plug

Cut off and dispose of the supplied plug if it does not fit your socket.

WARNING: To avoid a shock hazard do not insert the discarded plug into a socket
anywhere else.

IMPORTANT: WIRES IN THE

MAINS LEAD ARE COLOURED

IN ACCORDANCE WITH THE

FOLLOWING CODE:

Green/Yellow

-

Earth

Blue -

Neutral

Brown

-

Live

If you change the plug, the colour of

wires in the mains lead may not

correspond with the colour of the

markings identifying terminals in the

plug. You should therefore wire it as

shown.

Changing the Mains Lead

A special lead can be ordered from our Service Department UK: 08709 066 066 or

Republic of Ireland: 1850 302 200

If you have damaged the existing lead or require a longer one a charge will be made. It is

strongly advised that this work is carried out by a qualified electrician.

CE marking certifies that this appliance conforms to the following EEC directives:-
Low Voltage Equipment - 72/23/EEC & 93/68 EEC
Electromagnetic Compatibility - 89/336/EEC, 92/31/EEC & 93/68/EEC

3

Electrical Supply

Green and yellow (Earth)

wire to terminal

marked ‘E’,

symboL,

or

coloured green

and yellow.

Blue (Neutral)

wire to terminal

marked ‘N’ or

coloured black.

13A ASTA approved

fuse to BS1362.

Brown (Live)

wire to terminal

marked ‘L’ or

coloured red.

Cord clamp