Hickory industries, inc – HP Hickory Rotisseries 45WDG PLUS User Manual
Page 10
Hickory Industries, Inc.
4900 Westside Avenue, North Bergen, New Jersey 07047
Tel: [201] 223-0050 Fax: [201] 223-0950
N/45 Series Manual12/00
Page 10 of 38
Air Intake Adjustment
Lock Nut
Main Orifice
Venturi Tube
Venturi Assembly
1.9
Changing Gas Orifices
1.9.1
Changing the Main Gas Orifice
1.
The venturi tubes and manifold valves are on the same side as the spit handles.
2.
On each venturi, loosen the lock nuts (7/8" wrench) and then move the nut
and the air intake cap all the way to the top of the nipple.
3.
With a 3/4" wrench, loosen the nipple so that it can be removed from the
venturi.
4.
With the nipple/orifice assembly off, separate the main orifice from the
nipple with a pipe wrench or a pair of pliers.
Air Intake Cap
Nipple
Re-assemble all of the components with the new main orifice. Make sure that the proper air intake
adjustment is made for the new type of gas (according to the tables on page 9). The flames should be
blue in color, must be stable, and must not "lift off" the burner.