beautypg.com

Hot gas options for evaporators, 1 - low profiles, Hot gas reverse cycle kits (factory-installed) – Heatcraft Refrigeration Products BN-PL0208 User Manual

Page 29: Hot gas reverse cycle kits (shipped-loose)

background image

February 1, 2008 Bohn Refrigeration Products List Prices

29

Hot Gas Options For Evaporators

TXV Bypass Assembly Kits

(Hot Gas Loop (Standard) & Electric Drain Pan)

Hot Gas Reverse Cycle Kits (Factory-installed)

1 - LOW PROFILES

For Hot Gas models with the Hot Gas Loop Drain Pan ONLY

For Hot Gas models with the Hot Gas Loop Drain Pan ONLY

TXV Bypass Assembly Kits with TXV

(Hot Gas Loop (Standard) & Electric Drain Pan)

Hot Gas Reverse Cycle Kits (Shipped-loose)

1. Decide if kits are to be shipped-loose or factory-installed. If kits are to be shipped-loose, use the first two tables. If kits are to

be factory mounted, use the two tables at the bottom of the page.

2. Select the correct TXV bypass kit based on unit model number and TXV style. Selections for units with the electric drain pan

option are finished. For units with the standard hot gas drain pan, please proceed with steps 3 and 4.

3. Proceed to the table directly below the TXV bypass kit table and select the appropriate drain pan and suction-line check

valve kits based on unit model number. Drain pan and suction-line check valves and piping can be supplied by others but

are necessary to complete the piping.

4. If room temperature is 0°F or below, please select an insulated drain pan from table at the bottom of page 30 using the

appropriate unit model number. Selection for hot gas pan unit is finished.

REVERSE CYCLE HOT GAS DEFROST KIT SELECTION INSTRUCTIONS

When placing order, please specify:
• Unit model number
• Drain pan type (hot gas or electric)

(If ordering hot gas pan, indicate whether unit is to have insulated pan)

• Reverse cycle kit part numbers

(If ordering factory mounted kits, please specify TXV style, refrigerant,

saturated suction temperature (SST) and liquid temperature)

* The drain pan check valve kit can be ordered as an

independent item, but the suction-line check valve

kit must be ordered with the drain pan check valve

kit in order to complete the piping.

NOTE: TXV price and valve are NOT included in the

shipped-loose kits.

* The drain pan check valve kit can be ordered as an

independent item, but the suction-line check valve kit

must be ordered with the drain pan check valve kit in

order to complete the piping.

NOTE: TXV price is included in the bypass kit price

(factory-installed), BUT customer must specify valve

model, refrigerant and SST on order.

HGT 6 FPI

HGT 4 FPI

TXV Bypass Assembly Kits

List Price

Each ($US)

SQE/SBF

EG

HFESC

035 - 075

041 - 080

50169210

50169213

50169216

118

090 - 160

102 - 204

50169211

50169214

50169217

138

180 - 280

235

50169212

50169215

50169218

142

HGT 6 FPI

HGT 4 FPI

Drain Pan Loop

Check Valve Kit

List Price

Each ($US)

Suction-line

Check Valve Kit

List Price

Each ($US)

035 - 065

041

50169304

122

50169604

140

075 - 140

068 - 102

50169305

128

50169605

205

160 - 280

136 - 235

50169306

141

50169606

248

HGT 6 FPI

HGT 4 FPI

Drain Pan Loop

Check Valve Kit

List Price

Each ($US)

Suction-line

Check Valve Kit

List Price

Each ($US)

035 - 065

041

52733601

704

52733801

722

075 - 140

068 - 102

52733602

711

52733802

785

160 - 280

136 - 235

52733603

725

52733803

827

HGT 6 FPI

HGT 4 FPI

TXV Bypass Assembly Kits

List Price

Each ($US)

SQE/SBF

EG

HFESC

035 - 075

041 - 080

52733701

52733704

52733707

1,024

090 - 160

102 - 204

52733702

52733705

52733708

1,044

180 - 280

235

52733703

52733706

52733709

1,049

ADDITIONAL OPTIONS NEXT PAGE