beautypg.com

Installation 3. how to use, Location for power canister, Mounting the power canister – Hoover S5640 User Manual

Page 4

background image

4

2. Installation

3. How to use

Location for power
canister

The Power Canister can be mounted in
the basement, utility room, garage or
any other remote area, except where
exposed to weather, and convenient to
an electrical outlet. The unit requires
ventilation.

DO NOT

install in a heat pro-

ducing or confined area such as the
attic, furnace room, etc. If desired, the
Power Canister can be exhausted to the
outside.
The top of the Canister should be no
less than 12” (30.5 cm) from the ceiling
to allow proper cooling to the motor. For
ease of removing the dust container, the
bottom of the unit should be at least 6”
(16 cm) above the floor.
Central Vacuum Power Canisters require
a separate/dedicated, 120 Volt, 60Hz.,
20 Amp, 3 wire grounded power circuit,
protected by a 120 Volt, 60 Hz., AC, 20
Amp time delay fuse or circuit breaker
and a 120 Volt, 60 Hz., 20 Amp ground-
ed receptacle.
If a 120 volt, 60 Hz., 20 Amp grounded
receptacle is not available, have a quali-
fied electrician install one for you. The

receptacle should be no more than 5
feet (152 cm) from the Power Canister.

UNDER NO CIRCUMSTANCES
SHOULD AN EXTENSION CORD BE
USED WITH THIS CANISTER.

Mounting the power
canister

1)

Determine if the wall you will be
mounting the Canister to is block,
concrete, or plaster/drywall.

2)

Block or Concrete Wall

You will need (2) 1-1/2” (3.8 cm) x
1/4” (.64 cm) lead plugs and (2) 1-
1/2” (3.8 cm) x 1/4” (.64 cm) lag
bolts. Drill a 1/2” (1.3 cm) dia. x 1-
3/4” (4.4 cm) deep hole with a
masonry drill bit. Insert a lead plug
into the hole.

Mount the bracket (Fig. 2-1) from a
top hole with a lag bolt. Mark the
other upper hole of the bracket.
Make sure that the bracket is
straight. Slide the bracket away
from the mark and drill a hole direct-
ly over the mark.
Insert a lead plug into the hole.
Align the bracket over the hole and
tightly fasten with a lag bolt.
Continue to 4).

3)

Drywall or Plaster Wall

You will need(2) 1-1/2” (3.8 cm) x
1/4” (.64 cm) wood screws. Locate
a stud and drill a 1/8” (.32 cm) dia.
x 1-3/4” (4.4 cm) pilot hole. Mount
the bracket from a top hole with a
wood screw. Make sure that the
bracket is straight. Drill a second
pilot hole using a lower hole on the
bracket and fasten tightly with the
other wood screw.

4)

Mount the Power Canister on the
bracket making sure the bar on the
back of the machine is settled to the
bottom of the slots on the mounting
bracket. The wall mounting bracket
must fit between the two brackets
on the back of the central vacuum.

To start your Power Canister, simply plug
your hose end into any wall inlet valve.
Both types of wall valves (Standard (A) -
Corded Hose; Electrified (B) - Cordless
Hose) are shown in Fig 3-1.

3-1

A

B

If you have a hose without switches, the
Power Canister will start as soon as the
hose is inserted into the wall valve.

If you have a hose with a switch, then
the Power Canister can be turned ON or
OFF with the switch.

The Power Canister can also be turned
ON and OFF with the switch found on
the upper section of the motor module.

Check the System

Check each connection for proper seal
and that no air leaks occur. If one is pre-
sent, you may hear a “hissing” sound.
Correct if present.
Check each inlet valve for air leaks.
Start the system by plugging the hose
into each valve to make sure it functions
properly.
Your Central Vacuum Cleaning System is
now ready for your use.

2-1

5)

Route the intake tubing to the
Canister.

6)

Insert the tubing into the Canister
inlet.

7)

Tighten the inlet connection with the
3” (7.6 cm) gear clamp. (Do not
cement pipe to plastic inlet port.)

8)

Connect tubing to the exhaust (right
hand side near top of unit) and vent
outside (not necessary if unit is in
garage). Tighten the exhaust con-
nection with the clamp. (Do not
cement pipe to plastic exhaust
port.)

9)

Connect the 24 Volt wires coming
from the wall valves into the 24 Volt
receptacle on the machine.

10) Plug the power cord in.

11) Assuming that the wall inlet valves

are connected, the system is now
ready.

TOP

MOUNTING
BRACKET