HE420A STEAM POWER HUMIDIFIER

68-0192—4

6

an anticipated 20°F, the control automatically maintains the

indoor relative humidity in the safe, comfortable 35% range

(see Table 2).

OPERATION

The HE420A Humidifier uses the principle that hot water

creates water vapor. As dry air and vapor mix, the relative

humidity of the air rises. The humidity control monitors the

relative humidity and activates the humidifier accordingly.

When the humidity control calls for humidity, the humidifier

underwater heater starts heating the water in the humidifier

reservoir. When the water is warm enough, the humidifier

activates a relay that turns on the furnace fan. The warm dry

air from the furnace picks up the water vapor and circulates it

through the home. The fan continues to circulate the air until

the water cools down and then turns off the fan.

Humidified air feels warmer and more comfortable so you may

be able to lower the thermostat heating setpoint and save

money on heating fuel bills giving you a more comfortable

environment that is also energy efficient.

MAINTENANCE

A regular maintenance program prolongs the life of the

humidifier and provides a more comfortable environment.

Frequency of cleanings depends on water conditions. Either

hard or soft water can be used in the humidifier, but hard water

mineral deposits are more difficult to clean.

CAUTION

Voltage Hazard.

Can cause electrical shock and equipment damage.

Disconnect power supply before installing or servicing.

IMPORTANT

Never oil any part of the humidifier.

Every 1 to 4 Months

(Depending on Water Quality)

Use the following procedure and refer to Fig. 7 to clean the

humidifier:

1. Unplug the humidifier and fan control.

2. Disconnect the humidity control wires from the external

screw terminals on the humidifier.

3. Turn off the water supply.

Fig. 7. Location of humidifier parts.

4. Disconnect water feed tubing at the float valve.

5. Disconnect the overflow at the humidifier.

IMPORTANT

Allow water to cool before continuing.

6. Press and release the MANUAL button on the Automatic

Flushing Timer.

— Wait 10-30 seconds* until the flushing noise stops,

indicating that the flushing cycle is complete.

*The number of seconds will vary depending upon

how the unit is programmed. (See “Reprogramming

Instructions” in the Auto Flushing Timer Installation

Instructions)

— Repeat Steps A and B until the humidifier is drained.

7. Remove the humidifier from the mounting.

8. Use running tap water to flush loose minerals from the

reservoir.

9. Carefully rub off minerals from the float, heater, reservoir

walls, and safety float switch.

NOTE: Steel wool or other scouring pads can be used on the

reservoir walls and other parts.

10. Inspect the valve arm and float for mineral buildup and

deterioration.

IMPORTANT

• Replace the float valve when it shows any signs

of deterioration.

• The float valve should shut off the water at

2-3/8 in. (60 mm).

Table 2. Automatic Humidity Control Settings.

Outside Temperature

Recommended RH

+40°F

45%

+30°F

40%

+20°F

35%

+10°F

30%

0°F

25%

-10°F

20%

-20°F

15%

Table 3. Recommended Frost Factor Settings.

Humidity Level

Recommended Adjustment

Insufficient

humidity

Increase the frost factor dial by one setting.

Condensation on

windows

Decrease the frost factor dial by one setting.

M23367

Ho

ne

yw

ell

Hu

m

idif

ie

r M

od

el

HE

46

0

Fo

r R

es

ide

ntia

l U

se

O

nly

24

0 V

olts

, 1

P

ha

se

, 6

0 H

z, 1

50

0 W

atts

Da

ng

er:

P

os

sib

le e

lec

tric

sh

oc

k a

nd

bu

rn.

Dis

co

nn

ec

t e

lec

tric

al s

up

ply

an

d le

t w

ate

r c

oo

l

be

fore

se

rvic

in

g o

r c

lea

nin

g.

Ho

ne

yw

ell,

In

c. 1

88

5 D

ou

gla

s D

riv

e.

M

inn

ea

po

lis,

M

N 5

54

22

-39

92

R

Lis

ted

42

U8

R

Lis

ted

42

U8

SAFETY
FLOATSWITCH

HEATER

FLOAT

RESERVOIR

VALVE ARM

HUMIDITY
CONTROL

Hu

m

idit

y C

on

tro

l

gu

late

ur d

'H

um

id

ité

OU

TD

OO

R

TEM

PERA

TU

RE

HUM

ID

IT

Y

SE

TT

IN

G

-2

0F

-1

0F

0F

+1

0F

+2

0F

O

ve

r 2

0F

-30

C

-25

C

-20

C

-10

C

-5C

Over

0F

15%
20%
25%
30%
35%
40%

20

30

40

50

60