Maintenance schedule, 43 servicing your generator – HONDA EM5000is User Manual
Page 45

43
SERVICING YOUR GENERATOR
MAINTENANCE SCHEDULE
REGULAR SERVICE PERIOD (3)
ITEM
Each
use
Perform at every indicated month or
operating hour interval, whichever comes
first.
(1)
Failure to follow this maintenance schedule could result in non-warrantable failures.
For commercial use, log hours of operation to determine proper maintenance intervals.
These items should be serviced by your Honda servicing dealer, unless you have the proper
tools and are mechanically proficient. Refer to the Honda shop manual for service procedures.
Service more frequently when used in dusty areas.
Engine oil
Air Cleaner
Canister
(California type)
Purge tube
(California type)
Charge tube
(California type)
Sediment cup
Spark plug
Spark arrester
Valve clearance
Combustion
chamber
Fuel tank and filter
Fuel tube
Check level
Change
Check
Clean
Check
Check
Check
Clean
Check-adjust
Replace
Clean
Check-adjust
Clean
Clean
Check
Every 2 years (Replace if necessary) (2)
Every 2 years (2)
Every 2 years (2)
Every 2 years (2)
After every 500 Hrs. (2)
(2)
(2)
(1)
(2)
(3)
First
month
or
20 Hrs.
Every
3
months
or
50 Hrs.
Every
6
months
or
100 Hrs.
Every
year
or
300 Hrs.
Page