beautypg.com

Ec series installation instructions – Hearth and Home Technologies EC36 User Manual

Page 23

background image

08/04

17339 Rev L

23

EC SERIES INSTALLATION INSTRUCTIONS

Figure 22 - Installing a TR344 Round Termination Cap

Figure 23 - Installing a TR342 Round Telescoping

Termination Cap

2. Chase Top

Construct a chase of desired materials maintaining a
minimum 2 in. air space around the chimney.

3. Termination Cap

a.

Install the chimney sections up through the chase
enclosure. When using a TR344 round
termination cap, the uppermost top section of
pipe must extend 6 in. above the top of the chase
collar to allow installation of the storm collar and
termination cap. See Figure 22.

b.

For installations utilizing a TR342 telescoping
round termination cap, the uppermost chimney
section must be below the top of the chase top,
but not more than 14-1/2 in. below the top of the
chase top flashing collar. See Figure 23.