LEVELING

Merchandisers must be installed level
to ensure proper operation of the
refrigeration system and to ensure
proper drainage of defrost water.
When leveling merchandisers, use a
carpenter’s level as shown.

Metal leveling shims or wedges are
provided with each merchandiser for
use if needed.

NOTE: B

EGIN LINEUP LEVELING

FROM THE HIGHEST POINT OF THE

STORE FLOOR

.

Place shims under the rail and make
sure that they are positioned at a base
component (crossbar). This transfers
the weight directly from the loaded
case through to the floor. Placing shims
at other locations will cause uneven
distribution of weight leading to piping
leaks, as well as sagging or wracked
doors.

Reach-In

P/N 0387183_D

1-3

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

5-Door Island Shown

Bottom Front

Support

Skid/External Base

Electrical Wireway

Electrical Wireway

Shim

Here

NO SHIM

HERE

Base Component

Shim Here

Shim Here

Rear of Reach-in

Approximately
Centered

Base
Component