Item 93657

Operating Instructions

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this

manual including all text under subheadings therein before set up or use of this product.

Compressor Area Set Up

1. Designate a work area that is clean and well-lit.

The work area must not allow access by

children or pets to prevent injury.

2. Locate the Compressor on a flat level surface to

ensure proper pump lubrication and to prevent

damage to the unit. Keep at least 12″ of space

around the unit to allow air circulation.

3. Route the power cord from the compressor

to the grounded wall outlet, along a safe path

without creating a tripping hazard or exposing

the power cord to possible damage.

General Operation

1. Insert the Power Cord Plug (35) into the

nearest 120 volt, grounded, electrical outlet.

2. Connect an Air Brush (not included) to

the Air Hose (43) of the Compressor.

Use Hose Adapter (44) if needed.

Note: Use this Compressor only with air

brushes; do not use this compressor with

any other type of painting equipment.

3. Turn the Power Switch (34) on.

Note: The Compressor will automatically begin

to run when the air pressure falls below

43 PSI.

When the maximum air pressure (

58 PSI) is reached,

the Compressor will automatically switch to

idle and the Compressor will stop operating.

The Compressor will automatically restart

when the air pressure falls below

43 PSI.

4. Adjust the regulated air pressure output as

shown on the Pressure Gauge (11) by lifting

the Regulator Knob (40), turning it to the

desired pressure and pressing it back down.

5. When finished using the Air Compressor, turn its

Power Switch (34) off. Release any remaining air

in a safe fashion and disconnect the Air Brush.

Briefly depress the Water Drain Valve (41) to

empty the unit of water after each use.

6. Store the Air Compressor in a clean, dry,

safe location out of reach of children

and other unauthorized people.

SAFETY

OPERA

TION

MAINTENANCE

SETUP