Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Compressor Area Set Up
1. Designate a work area that is clean and well-lit.
The work area must not allow access by
children or pets to prevent injury.
2. Locate the Compressor on a flat level surface to
ensure proper pump lubrication and to prevent
damage to the unit. Keep at least 12″ of space
around the unit to allow air circulation.
3. Route the power cord from the compressor
to the grounded wall outlet, along a safe path
without creating a tripping hazard or exposing
the power cord to possible damage.
General Operation
1. Insert the Power Cord Plug (35) into the
nearest 120 volt, grounded, electrical outlet.
2. Connect an Air Brush (not included) to
the Air Hose (43) of the Compressor.
Use Hose Adapter (44) if needed.
Note: Use this Compressor only with air
brushes; do not use this compressor with
any other type of painting equipment.
3. Turn the Power Switch (34) on.
Note: The Compressor will automatically begin
to run when the air pressure falls below
43 PSI.
When the maximum air pressure (
58 PSI) is reached,
the Compressor will automatically switch to
idle and the Compressor will stop operating.
The Compressor will automatically restart
when the air pressure falls below
43 PSI.
4. Adjust the regulated air pressure output as
shown on the Pressure Gauge (11) by lifting
the Regulator Knob (40), turning it to the
desired pressure and pressing it back down.
5. When finished using the Air Compressor, turn its
Power Switch (34) off. Release any remaining air
in a safe fashion and disconnect the Air Brush.
Briefly depress the Water Drain Valve (41) to
empty the unit of water after each use.
6. Store the Air Compressor in a clean, dry,
safe location out of reach of children
and other unauthorized people.