Item 93657
Specifications
Electrical Rating
120V~ / 60Hz / 2A
Motor
1,750 RPM
Power Cord
6′ Long Power Cord (18AWG x 3C)
Thermal Protection
Automatic shut-off on overload/overheat and automatic reset
Maximum Air Pressure
/ Automatic Shut Off
58 PSI
Automatic Restart
43 PSI
Air Output
.5 CFM @ 20 PSI
Air Outlet Size
1/8″-28 NPS Air Outlet with 1/4″-18 NPT Male Adapter
Hose Dimensions
.236″ OD x .157″ ID x 10′ Long (1/8″-28 NPS Female Adapter - both sides)
Base Dimensions
7-3/8″ L x 5-3/8″ W x 1″ H
Setup - Before use:
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
TO PREVENT SERIOUS INJURY
FROM ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and unplug
the Air Compressor from its electrical
outlet before assembling or making any
adjustments to the compressor.
Note: For additional information regarding the
parts listed in the following pages, refer to the
Assembly Diagram near the end of this manual.
Before operating, make sure the Air Compressor is set
up in a well-ventilated area, on a flat, level, solid surface
well away from any flammable objects, such as drapes.
Never paint in an area without proper ventilation,
or near possible ignition sources.
Figure A: Functions
Power
Switch
(34)
Air Hose (43)
Water Drain
Valve (41)
Handle
(30)
Pressure
Gauge (11)
Pressure
Regulator (40)
SAFETY
OPERA
TION
MAINTENANCE
SETUP