beautypg.com

If you have a problem lubrication, Service – Hoover Sidewinder User Manual

Page 7

background image

7

3-21

1 = End cap without side projections

2 = Fiber washer

2

2

1

3

4

5

3 = Agitator crown for belt

4 = Large end

5 = End cap with side projections

If the end caps should fall off the agita-
tor, they are different from each other
and need to be properly oriented as
shown.

End caps should fit tightly on

agitator.

Problem: Cleaner won’t run

Problem: Cleaner won’t pick up

Problem: Dirt falling from cleaner

Possible cause

Possible solution

• Not firmly plugged in.

Plug in firmly.

• No voltage in wall plug.

Check fuse or breaker.

• Blown fuse/tripped breaker

.

Replace fuse/reset breaker.

Possible cause

Possible solution

• Dirt cup full.

Empty dirt cup.

• Nozzle, dirt passageway clogged.

Remove obstruction.

• Filter clogged.

Empty dirt cup and clean filter.

• Agitator brushes worn.

Repalce agitator.

• Broken or worn belt.

Replace belt.

Possible cause

Possible solution

• Flap on filter clogged or damaged.

Remove obstruction; replace filter
if necessary

If a minor problem develops, it usually
can be solved quite easily when the
cause is identified by using the check
list below.

4. If you have a

problem

Lubrication

The motor and agitator bearings are per-
manently lubricated. The addition of
lubricant could cause damage.

Therefore, do not lubricate the
cleaner.

Service

To obtain approved HOOVER service
and genuine HOOVER parts, locate the
nearest

Hoover Factory Service Center

or Authorized Hoover Warranty
Service dealer (depot)

by:

• checking the Yellow Pages under

“Vacuum Cleaners – Household”
OR–

• checking the list of Factory Service

Centers provided with this cleaner
OR–

• checking the Service section of

The Hoover Company on-line at

www.hoover.com

OR–

• calling 1-800-944-9200 for an auto-

mated referral of authorized service
outlet locations (U.S. only).

Do not

send your cleaner to the Hoover

Company in North Canton for service,
this will only result in a delay.

If further assistance is needed, contact
The Hoover Company Consumer
Response Center, North Canton, Ohio
44720, Phone: 330-499-9499.

In Canada, contact Hoover Canada,
Burlington, Ontario L7R 4A8,
Phone: 1-800-263-6376.

Always identify your cleaner by the

com-

plete

model number when requesting

information or ordering parts. (The
model number appears on the bottom of
the cleaner.)

Position agitator in nozzle and replace
bottom plate, screws and front cover fol-