11. Function setting and changes

BE-IR20 / 21

16

11-6 BE-IR21 internal sync

The BE-IR21 factory setting is for external sync. If required, this can be changed to internal

sync by changing chip parts.

Change the following chip parts for internal sync operation.

Sync system

R280

R281

R282

R284

External

Absent

0

100

Absent

Factory setting

Internal

100

Delete

Delete

0

0

Part code

RME1784

Type

ERJ3GEYJ0R00V

100

Part code

RME1797

Type

ERJ3GEYJ101V

(Main board side A)

(Main board side B)

Location of chip resistors