1. GENERAL
The appliance is designed to be mounted on a floor between two adjacent cabinets.
The cabinets must be securely fixed to the wall and the cooker securely fixed to the
cabinets.
This cooker must not be used free standing.
Note; This cooker must not be fitted on a platform.
3. FINAL INSTALLATION
a. Ensure that the adjacent cabinets and the gap between them have dimensions
in accordance with the diagram.
b. Assemble the plastic plugs provided into the fixing brackets. See diagram.
c.
Fix the fixing brackets to the sides of the adjacent cabinets so that the centre
line of the brackets are 565mm above the top of the plinth line and the front
face of the plastic plug is level with the front face of the cabinet sides. See diagram.
d. Adjust the feet on the cooker to their minimum position, i.e. fully screwed in.
e. Slide the cooker centrally into the space between the cabinets ensuring the
following:
i) The gap between the cabinet sides and the cooker is even along the length
of the cabinet sides.
ii) The cable is routed away from any vents in the rear panel and is not
trapped between the cooker and the wall, adjacent cabinets or under the
feet
f.
Adjust the feet using an open ended spanner until the bottom of the cooker door is
in line with the top of the plinth. Using a spirit level, check that the cooker is level in
all directions.
g. Check that the plinth can be fitted. If necessary re - adjust the feet and check that
the cooker is level. Then lock the feet into position by tightening the lock nut using
an open ended spanner.
h. Open the top oven door and fix the cooker to the brackets through the holes in
the side trims.
i.
Fix the plinth in position.
j.
Ensure that there is a minimum gap of 1mm between the cooker side trim and
the adjacent cabinet doors or drawer fronts.
k.
If a hob is to be installed directly above the cooker it must not project downwards
more than 20mm below the underside of the work top. Any projection of more than
10mm must not project more than 500mm from the wall.
INSTALLATION
33
Fig. 5