beautypg.com

Utilities required, Weights, Pressure ratio of pump – Henkel 9000 User Manual

Page 15: Specifications, cont. 13

background image

Specifications, cont.

13

14

Utilities Required:
Compressed air:
60 psig to 90 psig, filtered to 5 microns, dry (no condensing moisture).
Lubricated air not required.

Dimensions:
See Fig. 4 on page 13.

Product Viscosity Range:
100 cp - 100,000 cp

Cycle Rate:
Two Cycle per second maximum.

Amount of product dispensed per stroke:
Minimum = 0.02 cc.
Maximum = 0.40 cc.

Weight:
1.7 lbs.

Calculated Pressure Ratio for Loctite Part No. 983330 Series 9000 Rotospray Pump:

Calculated Pressure Ratios

Item

Air cylinder diameter

Device diameter

Ratio

Pump

1.125 inch

0.45 inch

5.0 : 1

w/ double 0.50 inch rod (pump piston)