Heat pump, Conventional – Hunter Fan 44132 User Manual
Page 2

HeaT PumP
Hunter
Carrier
Coleman
Comfortmaker
Bryant, Payne
Rheem Ruud
Trane,
Weathertron
York
Lennox (1)
Lennox (2)
R
R
R
R
R
R
R
R
R
V-VR
Y
Y or Y1
Y
Y
Y
Y
Y
Y
Y
M
E
W2
W2
W1
W2
W2
W
W
W1
Y
E
E
Jumper to W2
E
E
X2
Jumper to W2
E
E
O
O
O
O
O
O
O
R
B
B
B
G
G
G
G
G
G
G
G
G
F
L
L or F
L
L or X
L
L
X
L
C
C
X
C, X, X1
C, X, X1
X
B
B
C
X
Figure 4.
CoNveNTioNal
4 Wire Heat / Cool
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RH
Y
G
W
Jumper
Heat Power
Cool Contactor
Fan Relay
Heat Contactor
3 Wire Cool Only
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RC
Y
G
Jumper
Cool Power
Cool Contactor
Fan Relay
2 Wire Heat Only
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RH
W
Jumper
Heat Power
Heat Contactor
4 Wire with Common
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RH
Y
G
W
C
Jumper
Heat Power
Cool Power
Cool Contactor
Fan Relay
Heat Contactor
Common
5 Wire Heat / Cool
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
Heat Power
Cool Power
Cool Contactor
Fan Relay
Heat Contactor
RH
RC
Y
G
W
3 Wire Heat Only
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RH
G
W
Jumper
Heat Power
Fan Relay
Heat Contactor
3 Wire Hot Water with Damper Valve
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RH
W
A
Jumper
Heat Power
Heat Contactor
Damper Valve
Conventional Multi-Stage
The
rmo
st
at M
ount
in
g P
la
te
W
all
RH
RC
Y
G
W
W2
Y2
C
A
RC
Y
G
W
W2
Y2
Jumper
Heat Power
Cool Contactor
Fan Relay
Heat Contactor
Second Stage Heat
Second Stage Cool
Single Stage Heat Pump
The
rmo
st
at M
ount
in
g P
la
te
W
all
R
Y
G
L
O
B
Aux/E
Y2
C
R
Y
G
O
Jumper
Heat 24V Supply
Compressor Contact
Fan Relay
Cool Relay / Valve
The
rmo
st
at M
ount
in
g P
la
te
R
Y
G
L
O
B
Aux/E
Y2
C
Single Stage Heat Pump W/Aux Heat
W
all
R
Y
G
O
E
C
Jumper
Heat 24V Supply
Compressor Contact
Fan Relay
System Monitor*
Cool Relay / Valve
Auxiliary Heat
Common*
* The common wire “C” and system monitor wire “L” may or
may not be present.
L
Single Stage Heat Pump W/Heat Reversing
The
rmo
st
at M
ount
in
g P
la
te
W
all
R
Y
G
L
O
B
Aux/E
Y2
C
R
Y
G
B
C
Jumper
L
* The common wire “C” and system monitor wire “L” may or
may not be present.
E
Heat 24V Supply
Compressor Contact
Fan Relay
System Monitor*
Heat Relay / Valve
Auxiliary Heat
Common*
Multi-Stage Heat Pump
The
rmo
st
at M
ount
in
g P
la
te
W
all
R
Y
G
L
O
B
Aux/E
Y2
C
R
Y
G
L
O
E
Y2
C
Jumper
* The common wire “C” and system monitor wire “L” may or
may not be present.
Heat 24V Supply
Compressor Contact
Fan Relay
System Monitor*
Cool Relay / Valve
Auxiliary Heat
Second-Stage Cool
Common*