Heat pump, Conventional – Hunter Fan 44132 User Manual

Page 2

background image

HeaT PumP

Hunter

Carrier

Coleman

Comfortmaker

Bryant, Payne

Rheem Ruud

Trane,

Weathertron

York

Lennox (1)

Lennox (2)

R

R

R

R

R

R

R

R

R

V-VR

Y

Y or Y1

Y

Y

Y

Y

Y

Y

Y

M

E

W2

W2

W1

W2

W2

W

W

W1

Y

E

E

Jumper to W2

E

E

X2

Jumper to W2

E

E

O

O

O

O

O

O

O

R

B

B

B

G

G

G

G

G

G

G

G

G

F

L

L or F

L

L or X

L

L

X

L

C

C

X

C, X, X1

C, X, X1

X

B

B

C

X

Figure 4.

CoNveNTioNal

4 Wire Heat / Cool

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RH

Y
G

W

Jumper

Heat Power

Cool Contactor

Fan Relay

Heat Contactor

3 Wire Cool Only

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RC

Y
G

Jumper

Cool Power

Cool Contactor

Fan Relay

2 Wire Heat Only

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RH

W

Jumper

Heat Power

Heat Contactor

4 Wire with Common

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RH

Y
G

W

C

Jumper

Heat Power

Cool Power

Cool Contactor

Fan Relay

Heat Contactor

Common

5 Wire Heat / Cool

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

Heat Power

Cool Power

Cool Contactor

Fan Relay

Heat Contactor

RH
RC

Y
G

W

3 Wire Heat Only

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RH

G

W

Jumper

Heat Power

Fan Relay

Heat Contactor

3 Wire Hot Water with Damper Valve

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RH

W

A

Jumper

Heat Power

Heat Contactor

Damper Valve

Conventional Multi-Stage

The

rmo

st

at M

ount

in

g P

la

te

W

all

RH

RC

Y

G

W

W2

Y2

C
A

RC

Y
G

W

W2

Y2

Jumper

Heat Power

Cool Contactor

Fan Relay

Heat Contactor

Second Stage Heat
Second Stage Cool

Single Stage Heat Pump

The

rmo

st

at M

ount

in

g P

la

te

W

all

R
Y

G

L

O

B

Aux/E

Y2

C

R

Y
G

O

Jumper

Heat 24V Supply

Compressor Contact

Fan Relay

Cool Relay / Valve

The

rmo

st

at M

ount

in

g P

la

te

R
Y

G

L

O

B

Aux/E

Y2

C

Single Stage Heat Pump W/Aux Heat

W

all

R

Y
G

O

E

C

Jumper

Heat 24V Supply

Compressor Contact

Fan Relay

System Monitor*

Cool Relay / Valve

Auxiliary Heat

Common*

* The common wire “C” and system monitor wire “L” may or

may not be present.

L

Single Stage Heat Pump W/Heat Reversing

The

rmo

st

at M

ount

in

g P

la

te

W

all

R
Y

G

L

O

B

Aux/E

Y2

C

R

Y
G

B

C

Jumper

L

* The common wire “C” and system monitor wire “L” may or

may not be present.

E

Heat 24V Supply

Compressor Contact

Fan Relay

System Monitor*

Heat Relay / Valve

Auxiliary Heat

Common*

Multi-Stage Heat Pump

The

rmo

st

at M

ount

in

g P

la

te

W

all

R
Y

G

L

O

B

Aux/E

Y2

C

R

Y
G

L

O

E

Y2

C

Jumper

* The common wire “C” and system monitor wire “L” may or

may not be present.

Heat 24V Supply

Compressor Contact

Fan Relay

System Monitor*

Cool Relay / Valve

Auxiliary Heat

Second-Stage Cool

Common*