D/g-04 specifications, D/g-04 contents, Calculating required horsepower (kw) – HP G-04 User Manual
Page 2
2
D04-991-2400 5/1/04
Max Pressure
2,500 psi (170 bar)
Capacity @ Max Pressure
rpm
gpm
I/min
D/G-04-X
1750
2.9
11.0
D/G-04-E
1750
2.1
7.8
D/G-04-S
1750
1.6
6.1
Delivery @ Rated Pressure
revs/gal
500 psi
1500 psi
2500 psi
D/G-04-X
565
583
603
D/G-04-E
761
795
833
D/G-04-S
921
972
1,093
revs/liter
35 bar
100 bar
170 bar
D/G-04-X
149
154
159
D/G-04-E
201
211
224
D/G-04-S
244
257
287
Max Inlet Pressure
500 psi (35 bar)
Max Temperature
250
°
F (121
°
C) – consult factory for
temperatures above 160
°
F (71
°
C)
Inlet Port
D-04: 1/2 inch NPT
G-04: 1/2 inch BSPT
Discharge Port
D-04: 1/2 inch NPT
G-04: 1/2 inch BSPT
Shaft Diameter
7/8 inch (22.22 mm)
Shaft Rotation
Bi-directional
Bearings
Ball bearings
Oil Capacity
1.1 US quarts (1.05 liters)
Weight
37 lbs (16.8 kg)
Calculating Required
Horsepower (kW)*
+
6 x rpm
63,000
=
electric motor HP*
D/G-04 Specifications
+
6 x rpm
84,428
=
electric motor kW*
* rpm equals pump shaft rpm. HP/kW is required application
power. Use caution when sizing motors with variable speed
drives.
D/G-04 Contents
Page
Specifications ......................................................................... 2
Dimensions ............................................................................ 4
Installation .............................................................................. 5
Maintenance .......................................................................... 9
Service (Fluid End) .............................................................. 10
Service (Hydraulic End) ....................................................... 14
Troubleshooting ................................................................... 17
gpm x psi
1,460 –
(
)
psi – 500
20
gpm x bar
511 –
(
)
bar – 35
4