beautypg.com

If you have a problem, Clearing blockages – Hoover Upright Bagless Vacuum Cleane User Manual

Page 13

background image

13

Clearing blockages

Disconnect cleaner from electrical
outlet.

Low suction or pick up may be due to a
blockage in the system. Refer to the fol-
lowing steps to check for blockages

continuing with each step until the
blockage is found:

Turn cleaner OFF and disconnect from
electrical outlet.
1. Check fullness of dirt cup and filter
assembly; empty cup and clean filters if
needed.

4-2

D

A

C

B

Check airflow path

4. Plug cleaner in and turn ON. Check
for suction at end of hose (B).

a. If there is

suction,

continue with

step 5.

b. If there is

no suction,

check for

blockage in hose and dirt tube as
follows:

1) DIsconnect hose from dirt duct
(D) by reversing procedure for
“Attach hose” (Fig. 1-8 and 1-9).
2) Clear out hose.

4-3

E

Checking under bottom plate

6. Turn cleaner OFF and unplug.
7. Remove bottom plate, belt and agita-
tor (see “The belt” section).

Look into opening (E) for blockages and
remove.

8. Remove agitator shield (see Fig. 3-21)
and remove any loose debris which may
have accumulated under it.

4-1

Check dirt duct

2. Remove dirt cup, look in duct (A).
3. Clear blockage from dirt duct.

4. If you have a
problem

If a minor problem occurs, it usually can
be solved quite easily when the cause is
found by using the check list below.

Problem: Cleaner won’t run

Possible cause

Possible solution

• Not firmly plugged in

Plug unit in firmly

• No voltage in wall plug

Check fuse or breaker

• Blown fuse or tripped breaker

Replace fuse or reset breaker

• Thermal protector activated

Allow cleaner to cool for 30 minutes

(this will reset the thermal protector)
(see pg. 12).

Prob

Problem: Cleaner won’t pick up

Possible cause

Possible solution

• Broken or worn belt

Replace belt

• Agitator brush roll worn

Replace brush roll

• Dirt cup full

Empty cup

• Incorrect carpet height setting

Move nozzle control knob to lower

setting

• Blockage in air flow passage

Clear blockage

• Main filter clogged

Clean main filter by either tapping the

side of the dirt cup or removing the filter
as described in the “Filter assembly”
section

• Pre-filter clogged

Clean pre-filter as described in “Filter

assembly” section

• Dirt cup not properly installed

Position dirt cup properly and snap in

place (Fig. 3-4)

• Dirt cup lid not positioned properly

or missing

Ensure that dirt cup lid is properly

positioned

• Filter assembly not installed

properly

Ensure that pre-filter assembly and

main filter are positioned properly (Figs.
3-9 to 3-10)

Problem: Cleaner hard to push

Possible cause

Possible solution

• Incorrect carpet height setting

Move nozzle control knob to a
higher setting

Problem: Cleaning tools won’t pick up

Possible cause

Possible solution

• Dirt cup not properly installed

Position dirt cup properly and snap in

place (Fig. 3-4)

• Blockage in hose

Clear blockage

Problem: Visible dirt leaking through

final filter

Possible cause

Possible solution

• Filter assembly not installed

properly

Ensure that pre-filter assembly and

main filter are positioned properly

3) Look into (D) and remove block-
age.

5. Check connection at hose tube (C);