beautypg.com

Fig1), Front load washing machine model:slim3 – haier slim3 User Manual

Page 18

background image

Front Load Washing Machine Model:slim3

15















(Fig1)




Error message:Temperature sensor is not properly connected or damaged (display at the end of a
program).
Troubleshooting:























N

Cut off the power and choose spin program to
start, then check the import voltage of drain
pump, is it between AC 220-240 V?

Y

Replace drain pump

The wire between

PCB and drain
pump is not
connected
properly.
Replace the wire.

N

Cut off power and pull out water level
pressure switch wire connection. Set spin
program to start. Check the export voltage
to drain pump, is it between AC
220-240V?between blue wire and green
wire

Y

Replace PCB

Cut off power and measure the resistance

of temperature sensor by multimeter, is

it between 5-14kΩ?

Y

NTC exist open circuit .Replace it

N

Y

Check if NTC is connected properly

Connect NTC well

N

N

Disconnect the white wire and black wire
from PCB, and measure if the resistance
between blue wire and black wire of PCB is it
infinite?

N

Check the blue wire and black wire of NTC, are
they connected well?

Connect all wires well

Y

Replace PCB

Replace wire

Y