beautypg.com

Grounding, High altitude operation, Safety o pera tion m aintenance setup – Harbor Freight Tools Predator 6500 Watt Portable Generator 68526 User Manual

Page 8

background image

Item 68526 / 68529

Page 8

For Pump technical questions, please call 1-800-444-3353.

For Engine technical questions, please call 1-800-520-0882.

SAFETY

O

PERA

TION

M

AINTENANCE

SETUP

Initial Tool Set Up/Assembly

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this

manual including all text under subheadings therein before set up or use of this product.

Note: For additional information regarding the parts listed in the following pages,

refer to the Assembly Diagram near the end of this manual.

TO PREVENT SERIOUS INjURY:

Operate only with proper spark arrestor installed.

Operation of this equipment may create sparks that can start fires around dry vegetation.

A spark arrestor may be required.

The operator should contact local fire agencies for laws or

regulations relating to fire prevention requirements.

CAUTION: This generator is not intended to power sensitive electronic equipment without the addition of an

appropriate line conditioner and surge protector (both not included).

Sensitive electronic equipment includes,

but is not limited to, audio/video equipment, some television sets, computers, and printers. Sensitive

electronic equipment should be operated on approved inverter type generators or pure sine wave generators.

Note: Wheel Kit, item # 68531 (sold separately) can be used with this generator.

Grounding

The Generator must be properly grounded before

use. Have the unit grounded by a qualified

electrician if you are not qualified to do so.

To ground the Generator, connect a #6 AWG

grounding wire (not included) from the Grounding

Terminal on the Control Panel to a grounding rod

(not included) that has been driven at least 24

inches deep into the earth. The grounding rod must

be an earth-driven copper or brass rod (electrode)

which can adequately ground the Generator.

high Altitude Operation

The fuel system on this generator may be influenced

by operation at higher altitudes. Proper operation

can be ensured by installing an altitude kit when

required. See the table at right to determine when

an altitude kit is required. Operating this generator

without the proper altitude kit installed may increase

the engine’s emissions and decrease fuel economy

and performance. Kits should be installed by a

qualified mechanic. The kits may be requested

from Customer service. See parts list for details.

Altitude Range*

Kit Part Number

Up to 3000 ft

No modification needed

3000-6000 ft

#174

6000-8000 ft**

#175

* Elevation above sea level

** At elevations above 8000 ft, the engine

may experience decreased performance