Installation instructions – Hotpoint EG52 User Manual
Page 20
TECHNICAL DATA
DIMENSIONS
Height
900 - 915mm
Width
600mm
Depth
595mm (excluding door handles)
GENERAL
Gas connection
Rp
1
/
2
(
1
/
2
” BSP female)
Gas Supply
G20 at 20 mbar
Pressure test point
Grill injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 13A fuse.
Oven Heat Input
2.5kW
20
INSTALLATION INSTRUCTIONS
HEAT INPUT
BURNER
3.8 kW
GRILL
3.0 kW
HOTPLATE
Front left and rear right
1.8 kW
HOTPLATE
Front right and rear left
INJECTOR
150
134
109