beautypg.com

Troubleshooting, Please read the following carefully – Harbor Freight Tools 65204 User Manual

Page 15

background image

Page 15

For technical questions, please call 1-800-444-3353.

SKU 65204/

99918

troubleshooting

Problem

Possible causes

likely solutions

Low discharge

pressure

Air leaks.

1.

Leaking valves.

2.

Restricted air intake.

3.

Blown gaskets.

4.

Slipping belts.

5.

Listen for escaping air. Apply soap solution

1.

to all fittings and connections. Bubbles will

appear at points of leakage. Tighten or

replace leaking fittings or connections.
Remove head and inspect for valve

2.

breakage, weak valves, scored valve plate,

etc. Replace defective parts and reassemble.

Replace head gasket each time the head is

removed.
Clean or replace air filter element.

3.

Replace and gaskets proven faulty on

4.

inspection.
Tighten Belts (See monthly maintenance.)

5.

Follow all safety precautions whenever diagnosing or

servicing the tool.

Please read tHe FOllOWiNG careFullY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLy

DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLy. NEITHER THE MANUFACTURER OR

DISTRIBUTOR MAKES ANy REPRESENTATION OR WARRANTy OF ANy KIND TO THE BUyER THAT

HE OR SHE IS QUALIFIED TO MAKE ANy REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS

QUALIFIED TO REPLACE ANy PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/

OR DISTRIBUTOR ExPRESSLy STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD

BE UNDERTAKEN By CERTIFIED AND LICENSED TECHNICIANS, AND NOT By THE BUyER. THE

BUyER ASSUMES ALL RISK AND LIABILITy ARISING OUT OF HIS OR HER REPAIRS TO THE

ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER

INSTALLATION OF REPLACEMENT PARTS THERETO.

This manual is related to the following products: