Initial Installation
QUALIFIED INSTALLERS ONLY
C
ORNER
I
NSTALLATION
:
The dimensions for installing a fireplace in the corner of a room are given below in Figure 16.
R
AISED
F
IREPLACES
AND
H
EARTHS
:
There are a few options with raised fireplaces: raised with no hearth, raised with a raised hearth, or raised
with a floor level hearth. If the fireplace is 4 inches (101 mm) or more above the floor, a hearth is not
required. This measurement should be taken from the top of the flooring, i.e. the top of the carpet. The
fireplace cannot be placed within 37 inches (940 mm) of the ceiling. When installing a raised fireplace, it
is imperative that the support stand is strong enough to hold the weight of the fireplace and venting.
Figure 16. Dimensions for a corner installation.
Figure 17. Raised Fireplace with no Hearth
Figure 18. Raised Fireplace with Floor Level Hearth
15