Installation, Transit devices, Positioning – Electrolux I N F O EW 1262 W User Manual
Page 4: Water inlet
4
Transit devices
All transit bolts and packing must be removed before
using the appliance.
Proceed as follows:
Using a spanner, un-
screw and remove the
rear right-hand bolt and
lay the machine on its
back, taking care not to
squash the hoses. This
can be avoided by plac-
ing one of the corner
packing pieces between
the machine and the
floor.
Remove the polystyrene blocks from the underside of
the machine and release the two plastic bags by
removing the adhesive strip. Unscrew and remove the
feet. Carefully remove the right-hand bag (1) then the
left-hand bag (2) by pulling them towards the centre of
the machine.
Fit the grid on the bottom
of the machine and re-fit
the feet.
Set the machine upright and remove the two remain-
ing bolts from the back.
Pull out the three plastic pegs from the holes into
which the bolts were fitted.
Plug the open holes with the plugs which you will find
in the bag containing the instruction booklet.
Note: You are advised to keep all transit devices so
that they can be refitted if the machine ever has to be
transported again.
P0020
P0256
P0789
A
P0233
2
1
P0802
P0255
Positioning
Install the machine on a flat hard floor.
Make sure that air circulation around the machine is
not impeded by carpets, rugs etc. Check that the
machine does not touch the wall or other kitchen
units.
Carefully level by screwing the adjustable feet in or
out. Never place cardboard, wood or similar materials
under the machine to compensate for any uneven-
ness in the floor.
After having levelled the machine, tighten the lock
nuts.
Water inlet
Connect the water inlet hose to a tap with a 3/4"
thread after having inserted the small filter “A” sup-
plied with the machine.
The inlet hose must not be lengthened. If it is too short
and you do not wish to move the tap, you will have to
purchase a new, longer hose specially designed for
this type of use.
The other end of the inlet hose which connects to the
machine can be turned in any direction. Simply loosen
the fitting, rotate the hose and retighten the fitting,
making sure there are no water leaks.
P0021
A
P0003
P0509
P0254
INSTALLATION