PROBLEM SOLVING

Note: Turn off the switch and unplug the electrical cord before servicing.
For additional information call 1-800-282-2886 or visit our website at www.eureka.com

Problem

Cause

Solution

Suction Motor will not start

Electric plug

• Push plug securely into outlet

Agitator Motor will not start

• Try another outlet
• Check circuit breaker

Suction motor power switch and/or agitator

• Make sure power switch is in “ON” position

motor power switch are not turned “ON”

Cleaning solution and

Low water level in clean water tank

• Check the water level in the clean water tank and refill

water are not released
from the carpet nozzle

Clean water or detergent tank

• Be sure clean water tank and detergent tank are both locked

incorrectly installed

securely in place

Carpet nozzle area clogged

• Remove debris from the carpet nozzle area

Cleaning solution and

Low water level in clean water tank

• Check the water level in the clean water tank and refill

water are not released
from the Upholstery/stair

Clean water or detergent tank

• Be sure clean water tank and detergent tank are both locked

nozzle

incorrectly installed

securely in place

Clog in upholstery/stair nozzle

• Clear the Upholstery/stair nozzle of debris

Hose adapter not fully installed

• Press down firmly on hose adapter

Suction nozzle not correctly installed

• Make sure nozzle is fully engaged into adapter handle (see pg. 14)

Does not pick up the

Recovery tank is full

• Empty the recovery tank and return to cleaner. Resume cleaning

dispensed cleaning solution
and water from carpet

Recovery tank is not fully installed

• Make sure recovery tank is securely locked in position

Clear suction cover is not fastened at the corners

• Check to see that the suction cover release tabs are fastened properly

Hose attachment cover is not completely closed

• Press cover down firmly to snap closed

Does not clean the carpet

Improper cleaning solution used

• Use genuine Eureka Carpet/Upholstery Cleaning solution

Adjustable shampoo control lever in wrong

• Move lever upward to increase amount of detergent used

position

Agitator brush not installed correctly

• Make sure agitator brush is fully snapped into place and is allowed

to move freely

Agitator brush not moving

• Make sure power switch is in right position for agitation.

Minimal suction at the end

Upholstery/stair nozzle is clogged

• Remove any visible clogs from the nozzle that may restrict airflow.

of the hose

Hose adapter not fully installed

• Press down firmly on the hose adapter

Suction nozzle not correctly installed

• Make sure nozzle is fully engaged into adapter handle (see pg. 14)

Suction shuts off

Excessive foam in the recovery tank

• Empty recovery tank, then flush with clean water

prematurely

Improper cleaning solution used

• Use genuine Eureka Carpet/Upholstery Cleaning solution

Automatic suction shut off

Float may be binding in cage

• Remove automatic suction shut off assembly from recovery tank and

does not shut off

remove any hair or debris. Check for free movement of float in cage.