beautypg.com

General information, Maintenance – Empire Comfort Systems PV-28SV50-B User Manual

Page 45

background image

24820-1-0409

Page 45

GENERAL INFORMATION

Over Temperature Cut Out

The Mantis Power-Vent High-Efficiency Fireplace is protected

against overheating with a high temperature 80°C (176°F) cut off

switch to protect the heat exchanger, plastic sump and flue fan.
The high temperature cut off switch will automatically switch off

the gas supply to the heater, if the temperature in the room where

the heater is located reaches approximately 28°C (82.4°F). The

heater will go into lock out mode. An allowance of 15 minutes

minimum must be made to allow for the main fan to cool down

the heater prior to restarting the appliance.
Note: In most instances, overheating of the heater is a direct result

of too much lint and dust having accumulated in the main convec-

tion fan. This makes the fan unable to supply sufficient air to cool

down the heat exchanger. It is recommended that you inspect your

main convection fan prior to the start of the heating season and if

necessary have it serviced by a qualified service technician (refer

to Pages 45 and 46 - Maintenance).

Paint Curing - First Firing

The first fire in your heater is part of the paint curing process.

Your Mantis Power-Vent High-Efficiency Fireplace has been

painted with the highest quality heat resistant silicon paint avail-

able in the world.
To ensure that the paint is properly cured, light the unit and leave

it burning on high burn for approximately 1 hour.

1. During initial firing of this unit, its paint will bake out, and

smoke will occur. To prevent triggering of smoke alarms,

ventilate the room in which the unit is installed. During initial

firing of logs, you will detect an odor as the logs are cured.

Also, during the curing process the logs will burn with a yel-

low flame.

2. Don’t touch the surface of the heater. It will be soft during

this paint-curing phase. Once cured it will not be soft again.

3. The paint finish of the heater should not be cleaned with any

caustic or abrasive cleaning solutions.

4. Any damage to painted surface should be repaired with spe-

cial touch paint available from your Mantis Dealer.

MAINTENANCE

Note: Your appliance should be inspected, serviced and checked

annually by a qualified service person to ensure that your

appliance is operating safe and efficiently. Should you

detect any abnormality in the operation of your appli-

ance call a qualified service person who has been trained

and approved to inspect and service the appliance. This

may be your installer or dealer (routine service is not

covered under warranty).

This manual is related to the following products: