Figure 8: Mini Inlet and Outlet Location.

EXHAUST

Base of unit to center of flue

10

1

/

16

(255 mm)

Center of unit to center of flue

0”

(0 mm)

[at center of unit]

FRESH AIR INTAKE.

Base of unit to center of intake

61⁄8” (156 mm)

Center of unit to center of intake 2

1

/

16

(53 mm)

Outside fresh air is mandatory when installing

this unit in airtight homes and mobile homes.
A Fresh-air intake is strongly recommended for all

installations. Failure to install intake air may result in

improper combustion as well as the unit smoking during

power failures.
When connecting to an outside fresh air source, do not

use plastic or combustible pipe. A 2” minimum (51

mm) ID (inside diameter) steel, aluminum or copper

pipe should be used. It is recommended, when you

are installing a fresh air system, to keep the number of

bends in the pipe to a minimum.