Clearances to combustibles, Alcove clearances, Installation – Enviro C-10985 User Manual
Page 7
7
Installation
C
LEARANCES
TO
C
OMBUSTIBLES
:
IMPORTANT: Attach the Mini’s Hearth Pad when installing the unit on a combustible floor. The supplied
hearth pad meet all the requirement of a proper hearth pad. If you do not use the supplied hearth pad a
hearth pad must be used when on combustible material.
A
LCOVE
C
LEARANCES
:
This unit may be installed in an alcove. Maintain these clearances to combustibles.
Minimum Alcove width
36 inches (91.5 cm)
Minimum Alcove height 48 inches (122 cm)
Maximum Alcove depth 30 inches (76 cm)
Install vent at clearances specified by
the vent manufacturer.
S
id
e
W
al
l
Back Wall
Adja
cen
t W
all
8"
(20cm)
3"
(7.5cm)
4" (10cm)
36"
(91.5cm)
30"
(76cm)
48"
(122cm)
If the Mini is installed on carpet the use of a solid
material must be used under leveling legs.
These dimensions are minimum clearances but
it is recommended that you ensure sufficient
room for servicing, routine cleaning and
maintenance.
Side wall to unit 8 inches (20 cm)
Back wall to unit 4 inches (10 cm)
Corner to unit
3 inches (7.5 cm)
Figure 4: Mini Clearance to Combustibles.
Figure 5: Mini Minimum Alcove Size.