The pressure regulator and the burner orifices are set for LP gas.
To use natural gas, the regulator and burner orifices must be
converted.

To convert the range to NAT gas, follow these instructions:
1. Disconnect all electrical power at the main circuit breaker or

fuse box.

2. Shut off the gas supply to the range by closing the manual

shut-off valve.

Converting the Pressure Regulator

1. Locate the pressure regulator which can be found on the back

of the range on the right hand side if facing the back of the
range.

2. Unscrew the hex nut cap from the top of the regulator.
3. Unsnap the plastic plunger from the hex nut.
4. Reverse the plunger and reinstall onto the hex nut by

pressing firmly.

Note: Plunger is marked “Nat” and “LP”. Converted fuel type will
be shown on the lower portion of the plunger.

Converting the Surface Burners

1. Remove the top grates, burner caps, and burner heads.

2. Using a 9/32” or 7 mm nut driver remove the top burner

orifices. These may be accessed through the opening in the
burner base.

Note: Save these orifices for future conversion back to NAT gas, if
required.

3. Locate the proper NAT surface

burner orifices included with
the kit according to the
diagram below. The orifice
stamp can be either the metric
diameter size or the orfice drill size.

4. Install the orifices in their correct location. To prevent leakage,

make sure the orifice spuds are securely screwed into the
burner base.

W A R N I N G

The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and

requirements of the authority having jurisdiction. Failure to
follow

ALL

instructions could result in serious injury or

property damage. The qualified agency performing this
work assumes responsibility for this conversion.

NAT

LP

N AT

LP

Apply sideways finger pressure
to remove pin from cap.

N AT

LP

conversion

conversion

Orifice
spud

Burner
cap

Burner
grate

Burner
head

Burner
base

Orifice

stamp

0.79

Orifice

RNKR2 NAT Conversion Kit Instructions for RVGR3302/RVDR3302 Ranges

B

A

E

C

D

Part Number

Burner

BTU Rate

Diameter

mm

Orifice
Stamp

057747-901

Left front (A)

18,000

2.00

200

057747-902

Left rear (B)

9,100

1.38

138

057747-903

Center (C)

9,100

1.38

138

057747-905

Right rear (D)

12,000

1.58

158

057747-904

Right front (E)

17,000

1.88

189

015695-000

Bake

30,000

2.58

#38

PB040034

Broil

15,000

1.87

#50