Viking 3 Series 30 Inch Freestanding Gas Range LP/Propane Conversion Kit - RLPKR2 - Installation / Use and Care Instructions User Manual
Viking Stoves
1-EN
The pressure regulator and the burner orifices are set for Natural
gas. To use Liquid Propane gas, the regulator and burner orifices
must be converted.
To convert the range to LP gas, follow these instructions:
1. Disconnect all electrical power at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1. Locate the pressure regulator which can be found on the back
of the range on the right hand side if facing the back of the
range.
2. Unscrew the hex nut cap from the top of the regulator.
3. Unsnap the plastic plunger from the hex nut.
4. Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note: Plunger is marked “Nat” and “LP”. Converted fuel type will
be shown on the lower portion of the plunger.
Converting the Surface Burners
1. Remove the top grates, burner caps, and burner heads.
2. Using a 9/32” or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note: Save these orifices for future conversion back to Natural gas,
if required.
3. Locate the proper LP surface
burner orifices included with
the kit according to the chart
below. The orifice stamp can
be either the metric diameter
size or the orfice drill size.
4. Install the orifices in their correct location. To prevent leakage,
make sure the orifice spuds are securely screwed into the
burner base.
W A R N I N G
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow
ALL
instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
NAT
LP
N AT
LP
Apply sideways finger pressure
to remove pin from cap.
N AT
LP
conversion
conversion
Orifice
spud
Burner
cap
Burner
grate
Burner
head
Burner
base
Orifice
stamp
0.79
Orifice
RLPKR2 LP Conversion Kit Instructions for RVGR3302/RVDR3302 Ranges
Part Number
Burner
BTU Rate
Diameter
mm
Orifice
Stamp
057741-901
Left front (A)
16,000
1.19
119
057741-902
Left rear (B)
6,500
0.71
7
1
057741-903
Center (C)
8,000
0.8
5
8
5
057741-905
Right rear (D)
11,000
0.95
9
5
057741-904
Right front (E)
15,000
1.15
115
035282-000
Bake
30,000
1.68
1.68
035283-000
Broil
14,500
1.03
1.03
B
A
E
C
D
- 3 Series 30 Inch Freestanding Gas Range Natural Gas Conversion Kit - RNKR2 - Installation / Use and Care Instructions 3 Series 30 Inch Freestanding Dual Fuel Range LP/Propane Conversion Kit - RLPKR2 - Installation / Use and Care Instructions 3 Series 30 Inch Freestanding Dual Fuel Range Natural Gas Conversion Kit - RNKR2 - Installation / Use and Care Instructions