5 connecting the receiver to the power supply, Connecting the receiver to the power supply, Table 5 – Ericsson Advanced Modular Receiver RX8200 User Manual
Page 11: Fuse type and rating, Warning
Installing the Equipment
)
Type of Connector
Description
ASI/SD-SDI/HD-SDI
OUT 1 , 2 & 3
75
Ω BNC connector for ASI or SDI (user selectable)
output feeds.
ASI INPUT
75
Ω BNC connector for ASI input feed.
CONTROL 1 & 2
8-way RJ-45 connectors for 10/100BaseT Ethernet
control and monitoring.
AC POWER
IEC100-120 V AC / 220-240 V AC power input.
TECHNICAL EARTH
Spade connector for unit technical earth.
2.5
Connecting the Receiver to the Power Supply
Warning!
Do not overload wall outlets and extension cords as this can result in a risk of fire or
electric shock.
As no mains switch is fitted to this unit, ensure the local power supply is switched
OFF before connecting the supply cord.
The receiver is not fitted with an on/off switch. Ensure that the socket-outlet is
installed near the equipment so that it is easily accessible. Failure to isolate the
equipment properly may cause a safety hazard.
Connect the receiver to the power supply as follows:
1. Ensure the power supply is isolated and switched off.
2. Ensure the correct fuse type and rating has been fitted to both the equipment
and the power cable.
3. Connect the lead to the receiver input connector and then to the power supply.
4. Switch on the power supply.
Table 5
Fuse Type and Rating
Power Supply
Fuse Type and Rating
100-120 V AC / 220-240 V AC
IEC/EN 60127-2 Sheet 5
Bussmann S505/Littelfuse 215
2 A 250 V T HBC
Note: Refer to the Reference Guide for all power supply, fuse replacement, safety,
EMC information and operating conditions.
EN/LZT 790 0009 R1A
2011-03-30
11 (44