Hints for test institutes, Installation – Electrolux PRO STEAM TK SL5 E User Manual
Page 28

Use
Domestic
Permissible ambient temperature
+ 5°C to + 35°C
Consumption values
The consumption values have been established under standard conditions. They may de-
viate when the machine is operated in domestic circumstances.
Programme
Energy consumption in kWh / average
drying time in min.
Baumwolle (COTTON) Schranktrocken
(CUPBOARD DRY)
2)
3)
3.92 / 125 (7 kg load pre-drained at 1000
rpm)
3,75 (7 kg load pre-drained at 1200 rpm)
3,60 (7 kg load pre-drained at 1400 rpm)
3,20 (7 kg load pre-drained at 1800 rpm)
Baumwolle (COTTON) IRON DRY
2)
3.34 / 107 (7 kg load pre-drained at 1000
rpm)
Mischgewebe (SYNTHETICS) Schranktrock-
en (CUPBOARD DRY)
2)
1.33 / 48 (3 kg load pre-drained at 1200 rpm)
1) Different loading volume data may be needed in some countries as a result of different measuring
methods.
2) in accordance with EN 61121
Hints for test institutes
Parameters possible to be checked by the
Test Institutes:
• Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with nominal load.
• Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with half load.
• Final humidity (during cupboard dry cot-
ton, iron dry cotton and cupboard dry easy
care)
• Condensation efficiency (corrected with fi-
nal humidity) during cupboard dry cotton
cycle with nominal and half load (with
valve/filter of the water recirculation sys-
tem in OFF position).
All the cycles have to be checked in accord-
ance with EN 61121 (Tumble dryers for
household use – Methods for measuring the
performance).
Installation
Appliance positioning
• It is recommended that, for your conven-
ience, the machine is positioned close to
your washing machine.
• The tumble dryer must be installed in a
clean place, where dirt does not build up.
• Air must be able to circulate freely all round
the appliance. Do not obstruct the front
ventilation grille or the air intake grilles at
the back of the machine.
• To keep vibration and noise to a minimum
when the dryer is in use, it should be
placed on a firm, level surface.
• Once in its permanent operating position,
check that the dryer is absolutely level with
the aid of a spirit level. If it is not, raise or
lower the feet until it is.
• The feet must never be removed. Do not
restrict the floor clearance through deep
pile carpets, strips of wood or similar. This
might cause heat built-up which would in-
terfere with the operation of the appliance.
28 electrolux