3-WIRE INSTALLATION (GROUND IS THROUGH THE

NEUTRAL WIRE)

WARNING

Shock Hazard

The neutral wire and ground strap must be
connected as shown below for the range to be
properly grounded. Do not remove the ground strap.
Failure follow this instruction may result in potential
shock hazard.

WARNING

Fire hazard

Terminal block screws must be securely tightened.
Failure to do so may result in potential fire hazard.

FOR POWER CORD INSTALLATION
A.

Remove the 3 lower screws from the terminal

block. Do not loosen the upper screws.

B.

Do not cut or remove the ground strap.

C.

Insert the 3 screws through each power cord

terminal ring and back into the terminal block. Be
certain the white wire is in the center. Securely
tighten each screw (35 to 50 in-lbs.)

FOR CONDUIT INSTALLATION
A.

Loosen the 3 lower screws on the terminal block. Do
not loosen the upper screws.

B.

Do not cut or remove the ground strap.

C.

Insert the bare wire tip (insulation stripped 5/8”) into the

bottom terminal block openings. Be certain the white
wire is in the center. On certain models, the wire must
be inserted through an opening in the ground strap.
Securely tighten each screw onto each wire (35 to 50
in-lbs.).

D.

Reinstall terminal block cover.

NOTE:

Aluminum building wire may be used but it must

be rated for the correct amperage and voltage.

PROCEED TO STEP 8.

6

4-WIRE INSTALLATION (SEPARATE GROUND WIRE)

WARNING

The neutral wire of

the supply circuit must be connected to the
neutral terminal located in the lower center
of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of the terminal block. The
grounding lead must be connected to the
frame of the range with the ground plate and
the green ground screw.

FOR POWER CORD INSTALLATION
A.

Remove the 3 lower screws from the

terminal block. Do not loosen the upper
screws.

B.

Remove the ground screw and ground plate

and retain them.

C.

Cut the ground strap below the terminal

block and discard the lower section.

D.

Insert the ground screw through the ground

plate (removed earlier) and back into the
range frame. Tighten securely, but do not
over-tighten (15 to 20 in-lbs.)

E.

Insert the 3 terminal screws through each

power cord terminal ring and back into the
terminal block. Be certain the white wire is
in the center. Securely tighten each screw
(35 to 50 in-lbs.

F.

Reinstall terminal block cover.

FOR CONDUIT INSTALLATION
A.

Remove the 3 lower screws from the terminal

block. Do not loosen the upper screws.

B.

Remove the ground screw and ground plate

and retain them.

C.

Cut the ground strap below the terminal block

and discard the lower section.

D.

Insert the bare ground bare wire tip (insulation

stripped 5/8”) between the range frame and the
ground plate (removed earlier) and secure it in
place with the ground screw. Tighten securely,
but do not over-tighten (15 to 20 in-lbs).

E.

Insert the wire tips (insulation stripped 5/8”) into

the bottom terminal block openings. Be certain
the white wire is in the center. On certain
models, the wire must be inserted through an
opening in the ground strap. Securely tighten
each screw onto each wire (35 to 50 in-lbs.)

F.

Reinstall terminal block cover.

NOTE:

Aluminum building wire may be used but it must be rated for the correct amperage and voltage.

Ground

strap

Terminal block

(appearance

may vary)

Neutral

terminal

Power cord

Ground

plate

Power Cord

Red or

Black

Red or

Black

White

Terminal

block

Red or

Black

Red or

Black

Neutral

terminal

Ground plate

(grounding to

range)

Ground

screw

After–Power Cord

Green

or Bare

White

Before–Power Cord and Conduit

Terminal

block

Neutral

terminal

Ground

strap

Ground strap

or

After–Conduit

Terminal

block

Ground plate

(grounding to

range)

Wire

tips

Ground

screw

Red or

Black

Red or

Black

White

Green

or Bare

Wire

tips

Terminal

block

Conduit

Conduit

Red or

Black

Red or

Black

White