beautypg.com

Om_ec302-2.pdf, Wiring diagram esquema de cableado – Essick Air EC 302 User Manual

Page 3

background image

CAUTION: To reduce the risk of fi re or electri-
cal shock, do not use this fan with any solid state
speed control device.

Select the area you wish to cool. Evaporative
coolers work best near a partially opened door or
window to draw in fresh air. An equal amount of air
should be discharged out of the room to dispel heat
and humidity.

Fill the reservoir from the back. The reservoir holds
3 1/4 gallons of water. Pour water into the water
trough located in the lower portion of the back grille.
DO NOT OVER FILL. Water will leak out and could
cause water damage to the surrounding area. If the
reservoir runs dry, it will not harm the pump. When
transporting the unit to a different location, be very
careful not to spill the water. It is best to re-locate
the cooler, and then add water.

Plug the electrical cord into a 115-120 volt ground-
ed outlet. You may operate your cooler on one of
three speeds: low, medium or high. Turn the switch
knob clockwise to activate the pump and fan. This
will cool the air. Turn the switch counterclockwise
to operate the cooler as a fan only (pump will be
off).

When you operate your cooler without the water
circulating, it functions as a fan to circulate air.

Unpack your cooler and install the casters. Slip the
stems of the casters into the holes provided in the
bottom of the front and back grille.

CAUTION: To reduce the risk of fi re, always unplug
the cooler before attempting service of any kind.

No oil or lubrication is necessary. The motor is
permanently lubricated at the factory.

No oil or lubrication is necessary. Clean any debris
from under the pump in the inlet area.

The fi lter should be replaced each season, if it
becomes dirty or clogged.

Drain and clean the water tank. To drain, remove
the back grille and disconnect the clear hose from
the black tube. Turn unit on cool and pump out
most of the water. Wipe dry and clean with a towel.
Before reattaching the back grille, reconnect the
clear hose to the black water tube.

CAUTION: Always unplug the cooler before at-
tempting service of any kind.

POSSIBLE CAUSE/REMEDY:

1. The pump hose may have worked loose. Check
the connection at the pump and at the water tube
located in the back grille assembly. Reconnect
pump hose if necessary.

2. The water tube may be blocked. Remove the
tube and clean it out. Make sure water holes are
clear.

3. The pump or switch may be defective. Replace
pump or switch, if necessary.

POSSIBLE CAUSE/REMEDY:

1. Verify there is 115-volt power at the electrical
outlet. Check the fuse or breaker.

1. The fan switch or motor may be defective. Re-
place if necessary.

PROBLEM:

Cooler Does

Not Pump

Water

PROBLEM:

Fan Does Not

Operate

This warranty is extended to the original purchaser
only. It does not cover damages incurred during
shipping or through accident, neglect, or abuse by
the owner. Essick Air Products/Champion Cooler
does not authorize any person or representative to
assume any other or different liability in connection
with this cooler.

All original parts provided by Essick Air Products/
Champion Cooler are warranted against defects in
material or factory workmanship for one year.

Essick Air Products/Champion Cooler is not re-
sponsible for incidental or consequential damage
resulting from any malfunction.

Essick Air Products/Champion Cooler is not re-
sponsible for any damage occurring from the use of
water softeners, chemicals, de-scale material, or if
a higher horsepower motor is used in the unit other
than what Essick Air Products recommends.

Essick Air Products/Champion Cooler is not respon-
sible for the cost of service calls to diagnose cause
of trouble, or labor charge to repair and/or replace
parts.

Contact the Dealer where you purchased the
evaporative cooler. If for any reason you are not
satisfi ed with the response from the Dealer, contact
the Customer Service Department: Essick Air
Products, 5800 Murray Street, Little Rock, Arkansas
72209 or call 800-643-8341.

Register your product online at:
www.essickair.com/eac/onlineregistration-eac.htm

Terms And

Conditions Of

Warranty

Exclusions

From

Warranty

How To

Obtain

Service

Under This

Warranty

Register

Product

Motor

Pump

Filter

Water Tank

MAINTENANCE

LIMITED WARRANTY

TROUBLE SHOOTING

EVAPORATIVE COOLER

OPERATION

REPLACEMENT PARTS LIST
LISTA DE PIEZAS DE RECAMBIO

MOTOR

RED

BLACK

BLUE

WHITE

4

WHITE /

RIBBED

(COMMON)

BLACK /

SMOOTH

(HOT)

PUMP

3

2

A

B

1

RIBBED

SUPPLY

SMOOTH

115V

GREEN

3 SPEED

SWITCH

GREEN (GROUND)

WIRE NUT OR
CRIMP TERMINAL

DE 115V

MOTOR

BLANCO

AZUL

NEGRO

ROJO

4

NEGRO / LISO

BOMBA

2

3

1

LISO

VERDE

ACANALADO

INTERRUPTOR DE

3 VELOCIDADES

B

A

ABASTECIMIENTO

BLANCO /

ACANALADO

VERDE (TIERRA)

EMPALME PLASTICO

16

1 110845-12 Front

Grille

Rejilla

Anterior

2 110850-1 Reservoir

Depósito

De

Agua

3

110846-1

Fan Blade

Hoja De Ventilador

4 110441-3 Motor

Motor

5 110849-1 Handle

Asidero

6 110845-14 Knob

Perilla

7 110425-1 Switch

Interruptor

8 110718

Hose

Manga

9 110588-1 Tube

Tubo

10

110721

Tube Cap

Tapa Del Tubo

11

110845-11

Back Grille

Rejilla Posterior

12

250001-004

Pad Retainer

Soporte De Filtros

(2 req’d)

(2 req’d)

13

110394-1

Power Cord

Cable De Corriente

14

224135-001

Pump Mount

Soporte De La Bomba

15 110438

Pump

Bomba

16 110822-4

Casters

Ruedecilla

(4 req’d)

(4 req’d)

17

310124-1

Pad Set

Montaje De Filtros

No. Part

No.

Description

Descripción

WIRING DIAGRAM

ESQUEMA DE CABLEADO

Before

Operation

Fan