Periodic maintenance, Check engine oil level, Check battery charge – Exmark Lazer Z Advantage Series X User Manual
Page 30: Warning, Maintenance
Maintenance
Maintenance Service
Interval
Maintenance Procedure
Every 500 hours
• Replace the secondary air cleaner element (May need more often under severe conditions.
See the Engine Owner’s Manual for additional information.)
• Change the hydraulic filter and fluid.
• Check the wheel hub slotted nut torque specifications.
• Check the wheel lug nuts.
• Check the park brake adjustment.
Every 4,000 hours
• Change engine coolant. Dex-Cool© extended life coolant (orange color)
Yearly
• Grease the deck and pump idler pivots.
• Grease the front caster pivots.
Periodic Maintenance
Check Engine Oil Level
Service Interval: Before each use or daily
1. Stop engine and wait for all moving parts to stop.
Make sure unit is on a level surface.
2. Check with engine cold.
3. Clean area around dipstick. Remove dipstick
and wipe oil off. Reinsert the dipstick according
to the engine manufacturer’s recommendations.
Remove the dipstick and read the oil level.
4. If the oil level is low, wipe off the area around the
oil fill cap, remove cap and fill to the “FULL”
mark on the dipstick. Use oil as specified in
Engine Owner’s Manual. Do Not overfill.
Important: Do Not operate the engine with the
oil level below the “LOW” (or “ADD”) mark on
the dipstick, or over the “FULL” mark.
Check Battery Charge
Service Interval: As required
WARNING
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to the State of
California to cause cancer and reproductive
harm. Wash hands after handling.
Allowing batteries to stand for an extended period of
time without recharging them will result in reduced
performance and service life. To preserve optimum
battery performance and life, recharge batteries in
storage when the open circuit voltage drops to 12.4
volts.
Note: To prevent damage due to freezing, battery
should be fully charged before putting away for
winter storage.
Check the voltage of the battery with a digital
voltmeter or with the message display. If the ignition
key is turned to the “on” position for a few seconds,
the battery voltage will be displayed in the area where
the hours are normally displayed. Locate the voltage
reading of the battery in the table and charge the
battery for the recommended time interval to bring
the charge up to a full charge of 12.6 volts or greater.
Important: Make sure the negative battery cable
is disconnected and the battery charger used for
charging the battery has an output of 16 volts and
7 amps or less to avoid damaging the battery (see
chart for recommended charger settings).
Voltage
Reading
Percent
Charge
Maximum
Charger
Settings
Charging
Interval
12.6 or
greater
100%
16 volts/7
amps
No
Charging
Required
12.4 – 12.6
75–100%
16 volts/7
amps
30 Minutes
12.2 – 12.4
50–75%
16 volts/7
amps
1 Hour
12.0–12.2
25–50%
14.4 volts/4
amps
2 Hours
30