beautypg.com

Trouble shooting, Trouble probable cause suggested remedy – Emerson CF4600GLZ00 User Manual

Page 20

background image

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not

1. Fuse or circuit breaker

1. Check main and branch circuit fuses

start.

blown.

or circuit breakers.
WARNING: Make sure main power
is turned off.

2. Loose power line

2. Check line power connections to fan.

connections to the fan, or

3. Fan/Light Wall Control is OFF.

3. Turn ON Fan/Light Wall Control.

4. Code switches in remote control

4. Check that both code switches

receiver and Fan/Light Wall Control

are set in the same positions.

are not set in the same position

2. Fan sounds

1. Blades not attached to fan.

1. Attach blades to fan before

noisy.

operating.

2. Screws securing fan blade

2. Check to make sure the

flanges to mounting hub are

screws which attach the

loose.

blade flanges to the mounting
hub are tight.

3. Wire connectors inside

3. Check to make sure wire

switch cup rattling.

connectors in switch cup
are not rattling against each
other or against the interior
wall of the switch cup.
WARNING: Make sure main
power is turned off.

4. Screws holding blades to

4. Tighten screws securely.

flanges are loose.

5. Loose screws in motor

5. Check to make sure all

housing.

screws in motor housing
are snug (not over-tight).

3. Fan wobbles

1. Setscrew in motor coupling

1. Raise upper housing/glass and

excessively.

is not tightened securely.

coupling cover, then
tighten setscrew securely.

2. Setscrew in the hanger ball/

2. Tighten the setscrew in the

downrod assembly is loose.

hanger ball/downrod
assembly.

3. Screws securing fan blade

3. Check to be sure screws

flanges to mounting hub

which attach the fan blade

are loose.

flanges to the mounting hub
are tight.

4. Fan blade flanges not

4. Check to be sure that the

seated properly.

fan blade flanges seat firmly
and uniformly in the mounting
hub. If flanges are seated
incorrectly, loosen the flange
screws and retighten.

5. Hanger bracket and/or

5. Tighten the hanger bracket

ceiling outlet box is not

screws to the outlet box,

securely fastened.

and/or secure outlet box.

6. Fan blades out of balance.

6. Interchanging an adjacent

(side-by-side) blade pair can
redistribute the weight and
result in smoother operation.
Or use supplied balancing
kit to balance blades.

WARNING:

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX

OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

!

!

!

Part No. F40BP73060001
Printed in China 06/06

Form No. BP7306-1

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant ¥ St. Louis, MO 63136

BP7306 Nottingham 6/19/06 1:00 PM Page 20

This manual is related to the following products: