Page 3: Minimum dimensions

background image

3

INSTALLATION REQUIREMENTS

These installation instructions cover different models. The

appearance of your particular model may differ slightly from the

illustrations in these Installation Instructions.

Tools and Parts

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed

here.

Tools needed

Tape measure

#2 Phillips screwdriver

Drill

1/8" (3.17 mm) drill bit

Marker or pencil

Parts supplied

The Microwave Drawer is preassembled.

1" (2.5 cm) mounting screws (4)

1" (2.5 cm) deflector screws (2)

Flush mount deflector (1)

Optional Parts

27" (68.6 cm) Trim Kit (W11170223) for JMDFS24GS

27" (68.6 cm) Trim Kit (W11264778) for JMDFS24HM

Verification needed

Installer must confirm presence of anti tip block. Refer to the

anti-tip block section in the manual.

Check local codes. Check existing electrical supply. See

“Electrical Requirements”.

It is required that all electrical connections be made by a

licensed, qualified electrical installer.

Location Requirements

This product is suitable for use below electric or gas built-in

ovens. This product is not suitable for use below cooktops.
The Microwave Drawer may be located in a cabinet or below

the counter, and/or below a built-in oven. Check the opening

where the Microwave Drawer will be installed. The location must

provide:

IMPORTANT:

Observe all governing codes and ordinances.

Wood cabinetry.

Cutout opening that is plumb and square. See “Minimum

Cutout Dimensions” in the “Minimum Dimensions” section.

Cutout floor that is solid, level, and flush with bottom of

cabinet cutout.

Support for weight of at least 100 lbs (45.4 kg), which

includes Microwave Drawer and items placed inside.

Grounded electrical outlet. See the “Electrical Requirements”

section.

Minimum installation clearances for installation location. See

the “Minimum Dimensions” section.

Complete enclosure around the recessed portion of the

Microwave Drawer.

Minimum Dimensions

Minimum Wall Oven Combination Installation

Clearances

For proper installation, the following minimum clearances must

exist above and below the cutout opening.

NOTE:

Upper oven must have heat deflector kit installed to

direct exhaust away from microwave console (Refer to Wall Oven

Manual for Deflector Kit Installation)

A. Upper oven cutout
B. Microwave drawer cutout

2" (5.1 cm)

A

B

This manual is related to the following products: