Electrical, Installation requirements – Wolf E Series 30 Inch Built-in Microwave Oven Drop Down Door Installation Guide User Manual
Page 4
4
|
Wolf Customer Care 800.222.7820
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. A
separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
and may cause interruption of operation. Refer to the illus-
tration below for minimum power cord plug clearance.
WARNING
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove ground prong. Do not
use an adapter. Failure to follow these instructions can
result in electric shock, fire or death.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 120 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
4'
(1.2 m)
SPECIFICATIONS
Installation Requirements
The drop down door microwave oven can be installed in a
standard or flush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart.
For flush inset installations, a minimum
1
/
8
"
(3)
reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
If the drop down door microwave oven is installed above
or below a Wolf E series oven in a flush inset application, a
1
/
4
"
(6)
reveal is required.
INSTALLATION REQUIREMENTS
BASE SUPPORT
MIN
Drop Down Door Microwave
125 lb
(57 kg)
TRIM OVERLAP
24" MODEL
30" MODEL
Top
3
/
16
"
(5)
3
/
16
"
(5)
Bottom
0"
(0)
0"
(0)
Sides
11
/
16
"
(18)
3
7
/
8
"
(98)
3"
(76)
MINIMUM CORD
CLEARANCE
Power cord clearance.
Rating plate location.
RATING PLATE