Cabinet Dimensions - Flush Installation

A 23

1

/

4

" (59.0 cm) minimum cutout depth is required. These

dimensions will result in a 1/4" (6 mm) reveal on the top, a 1/4" (6
mm) reveal on the sides, and a 1/8" (3 mm) reveal on the bottom
of the microwave oven. The front face of the cleats and platform
will be visible and should be treated as a finished surface.

Front View

A

G

H

H

B

C

D E

F

I

Side View

J

K

27" (68.6 cm) Models

A.

5/8" (16 mm) top cleat*

B.

27

1

/

4

" (69.2 cm) minimum

width of flush inset cutout

C.

25

7

/

8

" (65.7 cm) minimum

width of opening

D.

19" (48.3 cm) minimum
height of flush inset cutout

E.

17

5

/

8

" (44.7 cm)

recommended cutout
height

F.

11/16" (1.7 cm) side cleat*

G.

3/4" (1.9 cm) bottom cleat*

H.

Recommended junction
box location

I.

40" (101.6 cm) bottom of
cutout to floor
(recommended)

J.

23

1

/

4

" (59.0 cm) minimum

depth of cutout

K.

1

3

/

8

" (3.5 cm) recess from

front of cabinet

30" (76.2 cm) Models

A.

5/8" (16 mm) top cleat*

B.

30

1

/

4

" (76.8 cm) minimum

width of flush inset cutout

C.

28

7

/

8

" (73.3 cm) minimum

width of opening

D.

19" (48.3 cm) minimum
height of flush inset cutout

E.

17

5

/

8

" (44.7 cm)

recommended cutout
height

F.

11/16" (1.7 cm) side cleat*

G.

3/4" (1.9 cm) bottom cleat*

H.

Recommended junction
box location

I.

40" (101.6 cm) bottom of
cutout to floor
(recommended)

J.

23

1

/

4

" (59.0 cm) minimum

depth of cutout

K.

1

3

/

8

" (3.5 cm) recess from

front of cabinet

*Cleats must be recessed 1

3

/

8

" (3.5 cm) from the front of the

cabinet.

Minimum Installation Clearances

For proper installation, the following minimum clearances must
exist above and below the cabinet opening.

Installation Above Single Built-In Oven

A. Upper cabinet
B. Lower single oven

Approved models: KMBP100E and KMBP107E

Electrical Requirements

GROUNDING INSTRUCTIONS

For a grounded, cord-connected appliance:

This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord having
an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.

WARNING:

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly grounded. Do
not modify the plug provided with the appliance: if it will not fit
the outlet, have a proper outlet installed by a qualified
electrician.

SAVE THESE INSTRUCTIONS

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.

Check with a qualified electrical installer if you are not sure the
oven is properly grounded.

This oven must be connected to a grounded metal, permanent
wiring system.

Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local
codes and ordinances.