The Remote Site

The Remote site is the extension of the EDA network. The Shared DSL
solution does not specify the full extent of the site, only the minimum
required functionality and basic elements.

4.1 Remote

Site

Elements

The remote site must contain at least the following elements:

• -48 VDC power supply

• 230 VAC outlet

• CPE

modem

• EPN102 EDA Power Node

• IP

DSLAM

• Necessary KRONE connectors for the IP DSLAM and EPN102

Depending on the type of installation and IP DSLAM used, an EDA filter
might also be necessary.

Note: Under usual circumstances, it is not necessary to have a battery

backup of the system, since the remote site is supplied with the
same power as the rest of the building.