beautypg.com

Product introduction, Product snapshot – Eaton Electrical Powerware Single-phase UPS 9155 User Manual

Page 2

background image

With advances in miniaturization and processing power, a single
rack of equipment demands more power than ever—and more
equipment will be served by dual cord power supplies. It’s a chal-
lenge to provide power protection for expanding loads in shrink-
ing spaces.

Fortunately, technology advancements have also raised the den-
sity per square foot of power protection systems. The Powerware
9155 and new Powerware 9355 uninterruptible power systems
(UPSs) deliver premium levels of efficiency, reliability and flexibil-
ity—all in a sleek tower half the size of most competitor units on
the market today.

These double-conversion, online UPSs resolve all nine common
utility power problems and supply clean, continuous power to
all connected equipment. Even when presented with the most
severe power problems, power output remains stable. And if the
utility power goes out altogether, there is no delay transferring to
backup power.

These capabilities make the Powerware 9155 and Powerware
9355 ideal for protecting essential data center, communications
and electrical engineering infrastructures in corporate, telecom,
healthcare, banking, public sector and industrial applications.

Features

• Protects connected equipment from all nine of the most

common power problems with true online, double-conversion
topology

• Delivers maximum power density in a compact tower

design, only 12” wide and 33” deep, including batteries

• Provides more real wattage in less space with a 0.9 power

factor—protecting more equipment for every utility dollar,
and leaving more room for expansion

• Delivers extra capacity or redundancy through patented

Powerware Hot Sync

®

paralleling of multiple modules

• Significantly increases battery life through microprocessor-

controlled ABM

®

technology

• Provides 0.99 power factor and generator friendly <5% total

harmonic distortion using an active IGBT rectifier to control the
input power factor

• Ensures data and system integrity with complete power man-

agement software for remote monitoring, management, and
shutdown

• Provides investment protection and peace of mind with an

Eaton factory limited warranty, technical support, and optional
service plans

Product Snapshot

Technology:

9155: Split-phase double-conversion

online UPS

9355: Three-phase double-conversion

online UPS

Power Rating:

9155: 8 kVA, 10 kVA, 12 kVA, 15 kVA

at 0.9 power factor

9355: 10 kVA and 15 kVA

at 0.9 power factor

Input Voltage:

9155: 200–240 Vac with Neutral or with

optional input isolation transformer

9355: 208V/120V or 220V/127V

Output Voltage: 9155: 100/200, 110/220, 120/240 Vac

180° phase displacement; 120/208,

127/220 Vac 120° phase displacement

9355: 208V/120V or 220V/127V

480:120V/208V or 600:120/208 with

input isolation transformer

(at 60 Hz only)

Frequency:

50/60 Hz auto-sensing

Dimensions:

Two-high configuration:

32.2” H x 12.0” W x 32” D

Three-high configuration:

47.8” H x 12.0” W x 33.5” D

Configuration:

Small-footprint tower, black

Battery Backup: 9155: Up to 29 minutes typical, extendable

up to four hours

9355: Up to 22 minutes typical, extendable

up to three hours

See Battery Back-up Times chart

Product Introduction