Replacing the burner injectors

1. Remove the pan supports.

2. Remove the burner's caps and crowns.

3. With a socket spanner 7 unscrew and remove the

injectors (Fig. 6), and replace them with the ones
required for the type of gas in use (see Table 2).

4. Reassemble the parts, following the same procedure

backwards.

5. Replace the rating label (placed near the gas supply

pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.

Should the feeding gas pressure be different or variable
compared with the required pressure, an appropriate
pressure adjuster must be fitted on the gas supply pipe,
in compliance with the rules in force.

Adaptation to different types of gas

Fig. 6

FO 0392

Adjusting the minimum level

To adjust the minimum level of the burners, proceed as
follows:

1. Light the burner.

2. Turn the knob on the minimum position.

3. Remove the knob.

4. With a thin screwdriver, adjust the by-pass screw

(see Fig. 7). If changing from natural gas to LPG,
completely tighten clockwise the screw, until a small
regular flame is obtained.

5. Finally check the flame does not go out when quickly

turning the knob from the maximum position to the
minimum position.

This procedure can easily be carried out, anyhow the hob
has been positioned or built in the working top.

BURNER

NORMAL

REDUCED

NORMAL

POWER

POWER

POWER

kW

kW

NATURAL GAS

LPG G30/G31

G20 20 mbar

28-30 mbar

inj. 1/100

m

3

/h

inj. 1/100 g/h - G30 g/h - G31

Auxiliary (small)

1,0

0,33

70

0,095

50

72

71

Natural gas :

Rapid (big)

3,0

0,65

119

0,286

86

203

200

LPG : 2,8

Burner

Ø By-pass

in 1/100

of mm.

Auxiliary

28

Rapid

42

Table 1 : BY-pass diameters

Table 2 : injectors

Fig. 7

By-pass screw