Electrical connection (not for UK)

Safety warnings for the electrician

Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to any
standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must
only be installed by an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector with a distance of at
least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be carried out by an
authorised electrician.

Electrical connection for UK only

Safety warnings for the electrician
Connect the hood to the mains supply via a double pole switch which
has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to

the terminal which is marked with the letter E or by the earth symbol
(

), or coloured green or green and yellow;

- the wire which is coloured blue must be connected to the terminal

which is marked with the letter N or coloured black, -

- the wire which is coloured brown must be connected to the terminal

which is marked with the letter L or coloured red.

BROWN

CORD CLAMP

BLUE

GREEN & YELLOW

5A

T