INSTALLATION INSTRUCTIONS

Technical information

DIMENSIONS

HEIGHT OF CANOPY:270mm
HEIGHT OF CHIMNEY:(UPPER SECTION)

215mm

(LOWER SECTION)

530mm

WIDTH OF CANOPY:EFC 635

598mm

EFC 935

898mm

DEPTH OF CANOPY:490mm

ELECTRICAL SUPPLY

VOLTAGE:(~50Hz)

220-240V

POWER CONSUMPTION:225W
FAN MOTOR:145W
LAMPS:(2 x40W)

80W

SUITABLE FOR -
INSTALLATION ABOVE:

ELECTRIC HOB:7KW (MAX)
GAS HOB:10KW (MAX)
SLOT-IN ELECTRIC COOKER:12.4KW (MAX)
SLOT-IN GAS COOKER:13.5KW (MAX)

THIS APPLIANCE MUST BE EARTHED

Electrical Requirements

Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).

Electrical Connection

Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker

Note: CE Marking certifies that this appliance complies with the
requirements laid down in EEC directive 89:336 (Electromagnetic
compatibility) and subsequent modifications and Low Votage directive
72/23/E.

This appliance is fitted with a 3 core mains cable
and must be permanently connected to the
electricity supply via a double-pole switch having
3mm minimum contact gap on each pole. A
Switched Fuse Connection Unit to BS.1363 Part
4, fitted with a 3 Amp fuse, is a recommended
mains supply connection accessory to ensure
compliance with the Safety Requirements
applicable to fixed wiring instructions.

This appliance conforms to BS.800:1988 and
EEC Directive No. 78 308 regarding suppression
of radio and television interference.