How to Check and

Clear Hose Blockages

Low suction or poor pick-up may be due to a

blockage in the vacuum cleaner.

Step 1: Remove hose from hose retainer on the

base and check suction at end of hose. If

little or no suction, check dust cup. Empty

if needed. If no improvement, proceed to

step 2.

CAUTION: Turn off the switch and unplug

the electrical cord before

clearing hose.

Step 2: Remove electrical cord from cord hooks.

Disconnect the clear tube by unscrewing

the 2 screws, then lift away from cleaner.

Check for any obstructions that may be

in the tube or hose. Obstructions may be

removed by using a blunt instrument to

clear the tube or hose. Flexing the hose

may help loosen the blockage. After

clearing blockage, reverse above steps to

reassemble unit. (FIG. 21)

Thermal Cut-Off

This cleaner has a special thermostat that protects

the cleaner in case of motor overheating. If the

cleaner suddenly turns off, follow this procedure:

Step 1: Push on/off switch to off.

Step 2: Unplug cleaner.

Step 3: Check for source of overheating problem

(i.e. full dust cup, clogged hose or clogged

filters).

Step 4: If a full dust cup, clogged hose or clogged

filters are found, empty the dust cup,

unclog the hose or replace the filters.

Step 5: Wait at least 30 minutes before attempting

to reuse the cleaner.

Step 6: After a 30-minute cool down period, plug

the cleaner in and push the switch pedal.

The cleaner should turn on.

Step 7: If the cleaner still does not operate,

please call Electrolux Customer Care on

08445 614614. Calls to this number will

be charged at 5p per minute at all times

from a BT Landline.