Dryer installations, Vented dryer dimensions, Edv278el technical data – Eurotech Appliances EWF272EL User Manual
Page 19

19
Specifications are subject to change without notice. See owner’s manual for additional details.
Dryer Installations
VENTED DRYER DIMENSIONS
EDV278EL
Technical Data
Drying system: External discharge
Supply voltage: 220/230 V, 60 Hz
Heater loading: 3300 watt
Fuse/breaker: 30 A
WARNING!
To reduce the risk of fire, vented dryers must be exhausted OUTDOORS or the equivalent.
This appliance should never be exhausted into a chimney, wall, ceiling, or concealed space
of a building. Use only a metal ventialtion grill.
Never cover the end of the dryer stub or vent hose with anything to catch lint, except for a
UL-approved vent basket.
This appliance must be properly grounded. Refer to the owner’s manual for instructions.
Installation should be carried out by a qualified person who is familiar with all local codes and ordinances
for electrical connections. Incorrect installation may cause damage and/or injury. You will need a UL-CSA-
approved exhaust hose. Excessive hose and too many bends can impede drying performance. Cut off
any excess hose and run the hose with as few bends as possible. Make any bends as gentle as possible.
There must be a ventilation outlet to the exterior for the exhaust hose. The machine can be installed in
any room with a hard floor. Do not install it on carpeting with heavy pile.
When placing the dryer next to a wall or cabinet, be sure to leave 1/2” (12 mm) of space between the
machine and the wall or cabinet.
See pages 23—28 for stacked washer/dryer dimensions.
39"
991 mm
23-1/4"
603 mm
33-1/4" 845 mm
23-3/8"
594 mm
3-1/2""
89 mm
9-3/8" 238 mm
11-1/2"
292 mm
Te
rm
ina
l
bo
x