beautypg.com

Emerson 1F97-391 User Manual

Page 12

background image

10

HM1 W RH RC G

Y

HM2 6

G

Y

5

3

2

4

RH

W

1

HM1

HM2

6

Y

G

W

RC

RH

E

D

C

H

J

I

M

K

L

1

From heating system

2

From 24 VAC transformer

3

Red jumper wire (provided)

4

From fan relay

5

From cool system

For humidifier wiring see pages 14-15.
See page 9 for letter identification.

NOTE: Ensure that RED RH/RC jumper wire (provided with
thermostat) is connected between thermostat's RH and RC
terminals for proper operation with this system.

NOTE: For three-wire heat only system, connect terminals

G

G

G

G

G,,,,, W

W

W

W

W

and

RH

RH

RH

RH

RH. For cool only system, connect terminals Y

Y

Y

Y

Y,,,,, G

G

G

G

G and RH

RH

RH

RH

RH.

Figure 4 – Typical wiring diagram for heat only, cool only, & heat/cool single transformer system