April 13, 2005

C-10857

Part Number

Option

50-1235

Horizontal Vent Kit

Flue Pipe Adaptor

Wall Framing

Wall Thimble

Fire Stop

Exhaust 4" Flex Pipe

Combusion Air 6 5/8" Flex Pipe

Wire Spacers

Horizontal Vent Termination

9. Install the fl ex pipe assembly through the wall thimble, ensure that this

portion of pipe slides through the outside wall far enough to connect onto

the vent termination cap.

10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm)

by 5” (12.5 cm) fl ue collar adaptor previously installed into the fi replace

fl ue outlet. Slide the Ø4” (10 cm) fl ex vent over the fl ue collar and secure

with three (3) sheet metal screws evenly spaced.

11. Place a bead of high temperature silicone on the intake collar of the

fi replace, slide the Ø6⅝” (16.25 cm) fl ex intake liner over the collar,

secure the fl ex liner with three (3) sheet metal screws evenly spaced.

12. On the outside of the

exterior wall, apply a

bead of Mill-Pac Black

sealant to the Ø 4” (10

cm) pipe of the vent

terminal. Slide the

fl ex liner onto the vent

terminal and secure with

three (3) sheet metal

screws evenly spaced.

13. Place a bead of high

temperature silicone on

the intake collar of the

vent terminal, slide the

Ø6⅝” (16.25 cm) fl ex

intake liner over the

collar, secure the fl ex liner

with three (3) sheet metal

screws evenly spaced.

14. Attach the vent terminal

to the outside of the

house using four (4)

wood screws provided.

15. Light the appliance and

ensure proper operation.

Figure 3

Figure 3