beautypg.com

Secondary installation – Enviro DV42DX User Manual

Page 33

background image

33

Figure 48: Final Log Set Arrangement with Embers.

Secondary Installation

Figure 49: DV42DX Burning.

Figure 47: Fourth Stage Log Set Installation.

Figure 47: The left log rests on the left pin

and ledge of the back log and the back of the

andiron.

Figure 48: The last log, center log, rests on

the end of the grate and on the ledge cut-out

in the center of the back log.
Once the logs are in place the embers can

be installed. Bags of ceramic fiber embers

and rock wool are provided. The ceramic

fiber comes in chunks that are about 2 inches

(5cm) long. Place them irregularly around the

burner. When there is a sparse but even layer

of embers, spread the rock wool in the same

manner. DO NOT pack the rock wool material

as this could create an unsafe condition. The

pieces should be lightly placed so they don’t

completely block any of the tiny ports. DO

NOT allow any of the embers to rest against

the pilot assembly.
Caution: Use only the type of ember material

supplied with this fireplace. Due to the

irregular size of the ember material, there

may be more than required. Use of other

foreign materials on the burners may create

dangerous conditions.

Figure 49: Refer to this figure when adjusting the venturi and vent restrictor. Make adjustments so that

the flame reaches the approximate height shown

NOTE: While the glass is still

removed, it is recommended that

the gas line be purged by lighting

the pilot.
When lighting the fireplace for

the first time since the log set

and embers have been installed/

replaced, watch for ignition at ALL

the burner ports. If a long delay

is noticed, turn the appliance off

and wait for it to cool down. Then

remove the glass and rearrange the

ember material, making sure none

of the burner ports are blocked.

This manual is related to the following products: